IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Anderson, M. L.
Right arrow Articles by Purple, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Anderson, M. L.
Right arrow Articles by Purple, R. L.

Investigative Ophthalmology & Visual Science, Vol 19, 278-288, Copyright © 1980 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

Circadian rhythms and variability of the clinical electro-oculogram

ML Anderson and RL Purple

Clinical electro-oculograms (EOGs) were recorded from six normal subjects over 24 hr time periods for a total number of 70 EOG'S. Results indicate an inverse relationship exists between the light/dark (L/D) ratio and the dark-trough potential. No relationship was found between the light-peak potential and the L/D ratio. Both the dark- trough potential and the L/D ratio showed a circadian periodicity over working daylight hours and rather aberrant behavior in late evening and early morning hours. Circadian contributions to the L/D ratio are estimated to be between 20% and 50% of the total variability in the normal individuals studied. We suggest the optimal time for single measurements of EOG pathology should be around midday.


This article has been cited by other articles:


Home page
J Biol RhythmsHome page
C. E. Reme, A. Wirz-Justice, and M. Terman
The Visual Input Stage of the Mammalian Circadian Pacemaking System: I. Is There a Clock in the Mammalian Eye?
J Biol Rhythms, March 1, 1991; 6(1): 5 - 29.