IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Herse, P. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Herse, P. R.

Investigative Ophthalmology & Visual Science, Vol 31, 2003-2007, Copyright © 1990 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

Corneal edema recovery dynamics in the rabbit. A useful model?

PR Herse
Department of Optometry, University of Auckland, New Zealand.

Open-eye and closed-eye recovery from contact lens-induced corneal edema was measured on the right eyes of 10 New Zealand White rabbits using ultrasound pachometry. Edema was produced by either 2 hours of eye closure (Patch Test) or 2 hours wearing of a thick hydrogel contact lens over the closed eye (Lens Test). The measured corneal edema recovery data were analyzed by both linear-regression analysis and nonlinear-regression analysis based on a previously published exponential open-eye edema recovery model. Linear-regression analysis revealed that the initial rabbit open-eye edema recovery rate of 36.3 +/- 11.9 (standard deviation) micron/hr was not significantly different (P greater than 0.25) from the initial young human open-eye edema recovery rate of 35.6 +/- 3.4 micron/hr. Similarly, the initial rabbit closed-eye edema recovery rate of 14.3 +/- 5.4 micron/hr was found to be not significantly different (P greater than 0.25) from the initial young human closed-eye edema recovery rate of 15.0 +/- 2.2 microns/hr. Corneal edema recovery indices derived using nonlinear-regression analysis also had a strong similarity between rabbit and human corneal edema recovery rates. For example, the calculated percent recovery per hour (PRPH) for rabbit open-eye corneal edema recovery of 41.4 +/- 11.3%/hr agreed well with the reported human open-eye PRPH of 34.2- 58.9%/hr. The rabbit closed-eye PRPH of 25.6 +/- 10.7%/hr was also found to lie between the calculated human closed-eye PRPH values of 19.9-30.2%/hr.(ABSTRACT TRUNCATED AT 250 WORDS)





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the Association for Research in Vision and Ophthalmology