IOVS British Journal of Pharmacology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Friedman, D. S.
Right arrow Articles by Schein, O. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Friedman, D. S.
Right arrow Articles by Schein, O. D.
(Investigative Ophthalmology and Visual Science. 1999;40:1715-1726.)
© 1999 by The Association for Research in Vision and Ophthalmology, Inc.

Digital Image Capture and Automated Analysis of Posterior Capsular Opacification

David S. Friedman1, Donald D. Duncan2, Beatriz Munoz1, Sheila K. West1 and Oliver D. Schein1

1 From the Dana Center for Preventive Ophthalmology, Wilmer Eye Institute, Baltimore, Maryland; and the 2 Applied Physics Laboratory, Johns Hopkins University, Laurel, Maryland.

PURPOSE. To develop and validate a digital imaging and analysis technique for assessing the extent of posterior capsular opacification after cataract surgery.

METHODS. Retroillumination images of the posterior capsule were obtained by using a digital camera mounted on a slit lamp. The images were analyzed using an available image analysis software program. The image acquisition and analysis techniques were tested for face validity, reproducibility, and the ability to detect progression of capsular opacity over time.

RESULTS. Digital retroillumination images were obtained without patient discomfort. Automated analysis of images correlated well with clinical grading both at slit lamp examination and when looking at the images themselves (Spearman’s correlation coefficient >0.7). Analysis of images taken at different times showed high reproducibility (intraclass correlation >0.9), and the system was able to identify progression of capsular opacity over a 2-year period with a mean increase of 15.8% in progressors versus an increase of 0.6% in nonprogressors (P < 0.05).

CONCLUSIONS. Digital retroillumination images of the posterior capsule can be obtained reliably, and automated analyses correlate well with clinical assessment. The system presented here uses commercially available instruments and software, and it is practical for use in longitudinal studies of posterior capsule opacification. It is reliable, easy to use, and can detect small changes in the percentage area covered by posterior capsule opacification over time.




This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
N Lois, R Dawson, J Townend, A D McKinnon, G C Smith, R v. Hof, N Van Rooijen, and J V Forrester
Effect of short-term macrophage depletion in the development of posterior capsule opacification in rodents
Br. J. Ophthalmol., November 1, 2008; 92(11): 1528 - 1533.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
D. Grewal, R. Jain, G. S. Brar, and S. P. S. Grewal
Pentacam Tomograms: A Novel Method for Quantification of Posterior Capsule Opacification
Invest. Ophthalmol. Vis. Sci., May 1, 2008; 49(5): 2004 - 2008.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
A H Ross, M V Mundasad, S M Neilson, E J Mayer, J M Sparrow, A D Dick, and D M Tole
In vivo measurement of opacified H60M intraocular lenses using Scheimpflug photography.
Br. J. Ophthalmol., October 1, 2006; 90(10): 1328 - 1329.
[Full Text] [PDF]


Home page
IOVSHome page
J. Moreno-Montanes, A. Alvarez, and M. J. Maldonado
Objective Quantification of Posterior Capsule Opacification after Cataract Surgery, with Optical Coherence Tomography
Invest. Ophthalmol. Vis. Sci., November 1, 2005; 46(11): 3999 - 4006.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
W. R. Meacock, D. J. Spalton, J. Boyce, and J. Marshall
The Effect of Posterior Capsule Opacification on Visual Function
Invest. Ophthalmol. Vis. Sci., November 1, 2003; 44(11): 4665 - 4669.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
O. Findl, W. Buehl, H. Siegl, and A. Pinz
Removal of Reflections in the Photographic Assessment of PCO by Fusion of Digital Retroillumination Images
Invest. Ophthalmol. Vis. Sci., January 1, 2003; 44(1): 275 - 280.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
T M Aslam, B Dhillon, N Werghi, A Taguri, and A Wadood
Systems of analysis of posterior capsule opacification
Br. J. Ophthalmol., October 1, 2002; 86(10): 1181 - 1186.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
S. A. Barman, E. J. Hollick, J. F. Boyce, D. J. Spalton, B. Uyyanonvara, G. Sanguinetti, and W. Meacock
Quantification of Posterior Capsular Opacification in Digital Images after Cataract Surgery
Invest. Ophthalmol. Vis. Sci., November 1, 2000; 41(12): 3882 - 3892.
[Abstract] [Full Text]


Home page
IOVSHome page
M. Camparini, C. Macaluso, L. Reggiani, and G. Maraini
Retroillumination versus Reflected-Light Images in the Photographic Assessment of Posterior Capsule Opacification
Invest. Ophthalmol. Vis. Sci., September 1, 2000; 41(10): 3074 - 3079.
[Abstract] [Full Text]

eLetters:

Read all eLetters

Measurement of Posterior Capsule Opacification in Retroilluminated Images
David John Spalton
IOVS Online, 29 Dec 1999 [Full text]
Authors' Response: Measurement of Posterior Capsule Opacification in Retroilluminated Images
Oliver Schein
IOVS Online, 29 Dec 1999 [Full text]



HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the Association for Research in Vision and Ophthalmology