IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barman, S. A.
Right arrow Articles by Meacock, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barman, S. A.
Right arrow Articles by Meacock, W.
(Investigative Ophthalmology and Visual Science. 2000;41:3882-3892.)
© 2000 by The Association for Research in Vision and Ophthalmology, Inc.

Quantification of Posterior Capsular Opacification in Digital Images after Cataract Surgery

Sarah A. Barman1, Emma J. Hollick2, James F. Boyce2, David J. Spalton2, Bunyarit Uyyanonvara1, Giorgia Sanguinetti1 and William Meacock2

1 From the Medical Imaging Unit, Department of Physics, Kings College; and the 2 Department of Ophthalmology, St. Thomas’ Hospital, London, United Kingdom.

PURPOSE. To describe a software program developed to provide an objective assessment of the amount of posterior capsular opacification (PCO) in high-resolution digital images of the posterior capsule after cataract surgery.

METHODS. Images are analyzed by a set protocol of defining the area of the posterior capsule, removing the Purkinje light reflexes by intensity segmentation, contrast enhancement, filtering to enhance low-density PCO, and variance analysis using a co-occurrence matrix to assess texture. The accuracy of the system was tested for validity and repeatability.

RESULTS. The software developed has been demonstrated to be an objective method of quantifying PCO. In validation tests, the image analysis–derived measure of PCO showed good agreement with clinically derived measures of PCO. Clinicians assessed PCO on a computer screen image and also under slit lamp examination (Pearson correlation coefficient for both methods >0.92). The entire acquisition and analysis system was demonstrated to have a confidence limit for 2 SDs of 9.8% for group data.

CONCLUSIONS. This system is capable of producing an accurate and reproducible measure of PCO that is relevant to assessing techniques of PCO prevention.




This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
N Lois, R Dawson, J Townend, A D McKinnon, G C Smith, R v. Hof, N Van Rooijen, and J V Forrester
Effect of short-term macrophage depletion in the development of posterior capsule opacification in rodents
Br. J. Ophthalmol., November 1, 2008; 92(11): 1528 - 1533.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
D. Grewal, R. Jain, G. S. Brar, and S. P. S. Grewal
Pentacam Tomograms: A Novel Method for Quantification of Posterior Capsule Opacification
Invest. Ophthalmol. Vis. Sci., May 1, 2008; 49(5): 2004 - 2008.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. Moreno-Montanes, A. Alvarez, and M. J. Maldonado
Objective Quantification of Posterior Capsule Opacification after Cataract Surgery, with Optical Coherence Tomography
Invest. Ophthalmol. Vis. Sci., November 1, 2005; 46(11): 3999 - 4006.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
W. R. Meacock, D. J. Spalton, J. Boyce, and J. Marshall
The Effect of Posterior Capsule Opacification on Visual Function
Invest. Ophthalmol. Vis. Sci., November 1, 2003; 44(11): 4665 - 4669.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
O. Findl, W. Buehl, H. Siegl, and A. Pinz
Removal of Reflections in the Photographic Assessment of PCO by Fusion of Digital Retroillumination Images
Invest. Ophthalmol. Vis. Sci., January 1, 2003; 44(1): 275 - 280.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
T M Aslam, B Dhillon, N Werghi, A Taguri, and A Wadood
Systems of analysis of posterior capsule opacification
Br. J. Ophthalmol., October 1, 2002; 86(10): 1181 - 1186.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the Association for Research in Vision and Ophthalmology