IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kutzko, K. E.
Right arrow Articles by Wall, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kutzko, K. E.
Right arrow Articles by Wall, M.
(Investigative Ophthalmology and Visual Science. 2000;41:2006-2013.)
© 2000 by The Association for Research in Vision and Ophthalmology, Inc.

Effect of Instructions on Conventional Automated Perimetry

Kim E. Kutzko1,3, Caridad F. Brito2 and Michael Wall1

1 From the Departments of Ophthalmology and Neurology, University of Iowa, College of Medicine, Iowa City; and the 2 Department of Psychology, Eastern Illinois University, Charleston.

PURPOSE. To investigate the effect of perimetrists’ instructions on automated perimetry thresholds.

METHODS. Eighteen volunteers in two age groups participated in a series of three test sessions. Each session consisted of a Humphrey Field Analyzer 30-2 test, a questionnaire, and a customized test program using a Humphrey perimeter to construct frequency of seeing (FOS) curves from which thresholds were calculated, and a descriptive measure of response criterion was derived. The FOS curves were obtained at a central and a peripheral test location within the same test session. The three test sessions differed only by the instructions given. The instructions were adapted from those listed in the manufacturer’s instruction manual and were designed to influence participants to respond to the stimuli in a conservative, liberal, or neutral manner.

RESULTS. For the 30-2 threshold test, a significant difference in mean deviation was found among the three instruction types (P = 0.001) and between the two age groups (P = 0.001). Although differences were small in the younger subjects (2.04 dB), the means for the responses from liberal to conservative differed by 6.57 dB in the older subjects. Thresholds obtained in a peripheral location by the customized threshold test were found to differ significantly between the age groups (younger group mean, 31.0 dB; older group mean, 27.2 dB) and among the instruction types (liberal mean, 30.9 dB; conservative mean, 28.1 dB; and neutral mean, 30.3 dB; P < 0.001). The descriptive measurement of response criterion suggests that a difference in criteria occurred as a result of the instructions in both peripheral and central locations for both age groups (P = 0.0001). In addition, according to self-reports, liberal instructions caused participants to be more likely to respond, whereas the conservative instructions caused them to be more reluctant to respond.

CONCLUSIONS. Perimetrists’ instructions can significantly affect obtained automated perimetry thresholds.




This article has been cited by other articles:


Home page
IOVSHome page
M. Wall, K. R. Woodward, and C. F. Brito
The Effect of Attention on Conventional Automated Perimetry and Luminance Size Threshold Perimetry
Invest. Ophthalmol. Vis. Sci., January 1, 2004; 45(1): 342 - 350.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. M. McKendrick, A. J. Anderson, C. A. Johnson, and B. Fortune
Appearance of the Frequency Doubling Stimulus in Normal Subjects and Patients with Glaucoma
Invest. Ophthalmol. Vis. Sci., March 1, 2003; 44(3): 1111 - 1116.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
H Sherafat, P G D Spry, A Waldock, J M Sparrow, and J P Diamond
Effect of a patient training video on visual field test reliability
Br. J. Ophthalmol., February 1, 2003; 87(2): 153 - 156.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. J. Anderson and C. A. Johnson
Mechanisms Isolated by Frequency-Doubling Technology Perimetry
Invest. Ophthalmol. Vis. Sci., February 1, 2002; 43(2): 398 - 401.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
P. H. Artes, D. McLeod, and D. B. Henson
Response Time as a Discriminator between True- and False-Positive Responses in Suprathreshold Perimetry
Invest. Ophthalmol. Vis. Sci., January 1, 2002; 43(1): 129 - 132.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the Association for Research in Vision and Ophthalmology