IOVS Journal of Cell Biology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bengtsson, B.
Right arrow Articles by Heijl, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bengtsson, B.
Right arrow Articles by Heijl, A.
(Investigative Ophthalmology and Visual Science. 2000;41:2201-2204.)
© 2000 by The Association for Research in Vision and Ophthalmology, Inc.

False-Negative Responses in Glaucoma Perimetry: Indicators of Patient Performance or Test Reliability?

Boel Bengtsson and Anders Heijl

From the Department of Ophthalmology, Malmö University Hospital, Sweden.

PURPOSE. To study whether false-negative answers in computerized glaucoma perimetry indicate the patient’s ability to perform perimetry or test result reliability.

METHODS. A retrospective evaluation was performed of visual field test results obtained with a perimetry program (Humphrey 30-2 Sita Standard; Humphrey Instruments, San Leandro, CA) in 70 consecutive patients with unilateral glaucomatous field loss. Frequencies of false-negative answers were compared between the two eyes of each patient and related to amount of visual field damage in the glaucomatous eyes using linear regression analysis.

RESULTS. Frequencies of false-negative answers were higher in eyes with field loss. The intrapatient intereye difference was 6.6% on average (P < 0.0001). In seven subjects with false-negative frequency of 5% or more in both eyes, the mean difference was 12.7% between eyes. The differences in false-negative answers depended significantly on the amount of field loss in the glaucomatous eyes (P = 0.0003). Larger differences were seen in patients with advanced field loss in the affected eye.

CONCLUSIONS. The increased frequencies of false-negative answers in eyes with field loss were strongly associated with field status. The higher false-negative frequencies in eyes with glaucomatous field loss compared with unaffected eyes may be explained by the increased variability in threshold values typically found in such eyes. False-negative answers in patients with glaucoma therefore represent eye rather than patient status.




This article has been cited by other articles:


Home page
IOVSHome page
A. Hot, M. W. Dul, and W. H. Swanson
Development and Evaluation of a Contrast Sensitivity Perimetry Test for Patients with Glaucoma
Invest. Ophthalmol. Vis. Sci., July 1, 2008; 49(7): 3049 - 3057.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
Y. Barkana, Y. Gerber, R. Mora, J. M. Liebmann, and R. Ritch
Effect of eye testing order on automated perimetry results using the Swedish Interactive Threshold Algorithm standard 24-2.
Arch Ophthalmol, June 1, 2006; 124(6): 781 - 784.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
B. Bengtsson, D. Bizios, and A. Heijl
Effects of Input Data on the Performance of a Neural Network in Distinguishing Normal and Glaucomatous Visual Fields
Invest. Ophthalmol. Vis. Sci., October 1, 2005; 46(10): 3730 - 3736.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
P. Asman, J. M. Wild, and A. Heijl
Appearance of the Pattern Deviation Map as a Function of Change in Area of Localized Field Loss
Invest. Ophthalmol. Vis. Sci., September 1, 2004; 45(9): 3099 - 3106.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the Association for Research in Vision and Ophthalmology