IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Melmoth, D. R.
Right arrow Articles by Rovamo, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Melmoth, D. R.
Right arrow Articles by Rovamo, J. M.
(Investigative Ophthalmology and Visual Science. 2000;41:2811-2819.)
© 2000 by The Association for Research in Vision and Ophthalmology, Inc.

The Effect of Contrast and Size Scaling on Face Perception in Foveal and Extrafoveal Vision

Dean R. Melmoth, Heljä T. Kukkonen, Pia K. Mäkelä and Jyrki M. Rovamo

From the Department of Optometry and Vision Sciences, Cardiff University, United Kingdom.

PURPOSE. To determine whether face perception can be equalized across the visual field by scaling size and contrast simultaneously.

METHODS. Contrast sensitivities were measured for detection (N = 1) and identification (N = 2–8) of a target face as a function of size (0.4o–10o) across eccentricities (E = 0o–10o).

RESULTS. In all conditions contrast sensitivity first increased and then saturated, as a function of stimulus size. Maximum sensitivity (Smax) decreased, whereas critical size (where S = Smax/) increased with eccentricity and set size (N). At each set size, sensitivities from all eccentricities could be equated by double scaling—i.e., translation in horizontal (size) and vertical (contrast) dimensions on log–log axes. Similarly, at each eccentricity, data from all set sizes could be superimposed using double scaling. Furthermore, all data could be superimposed onto the foveal detection curve when double scaled according to the equation F = 1 + E/E2i + logN/logN2i + E(logN)/K, where i is horizontal or vertical. This equation incorporates the eccentricity (E2) and set size (N2), where contrast and size double, as well as the interaction term (K).

CONCLUSIONS. Double scaling superimposes data. Not only is this possible across set sizes or eccentricities separately, but by combining their effects, a function is provided that collapses all data to a single curve, explaining all performance variation across eccentricity and set size. Our results support the proposition based on numeral recognition that failures of spatial scaling across eccentricities may simply reflect the need for scaling both size and contrast.




This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
L Tejeria, R A Harper, P H Artes, and C M Dickinson
Face recognition in age related macular degeneration: perceived disability, measured disability, and performance with a bioptic device
Br. J. Ophthalmol., September 1, 2002; 86(9): 1019 - 1026.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the Association for Research in Vision and Ophthalmology