IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Palanker, D. V.
Right arrow Articles by Blumenkranz, M. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Palanker, D. V.
Right arrow Articles by Blumenkranz, M. S.
(Investigative Ophthalmology and Visual Science. 2001;42:2673-2678.)
© 2001 by The Association for Research in Vision and Ophthalmology, Inc.

Pulsed Electron Avalanche Knife (PEAK) for Intraocular Surgery

Daniel V. Palanker1,2, Jason M. Miller1, Michael F. Marmor1, Steven R. Sanislo1, Philip Huie1,2 and Mark S. Blumenkranz1

1 From the Department of Ophthalmology, School of Medicine and 2 W. W. Hansen Experimental Physics Laboratory, Stanford University, Stanford, California.

PURPOSE. To develop a better and more economical instrument for precise, tractionless, "cold" cutting during intraocular surgery. The use of highly localized electric fields rather than laser light as the means of tissue dissection was investigated.

METHODS. A high electric field at the tip of a fine wire can, like lasers, initiate plasma formation. Micrometer-length plasma streamers are generated when an insulated 25 micron (µm) wire, exposed to physiological medium at one end, is subjected to nanosecond electrical pulses between 1 and 8 kV in magnitude. The explosive evaporation of water in the vicinity of these streamers cuts soft tissue without heat deposition into surrounding material (cold cutting). Streamers of plasma and the dynamics of water evaporation were imaged using an inverted microscope and fast flash photography. Cutting effectiveness was evaluated on both polyacrylamide gels, on different tissues from excised bovine eyes, and in vivo on rabbit retina. Standard histology techniques were used to examine the tissue.

RESULTS. Electric pulses with energies between 150 and 670 µJ produced plasma streamers in saline between 10 and 200 µm in length. Application of electric discharges to dense (10%) polyacrylamide gels resulted in fracturing of the gel without ejection of bulk material. In both dense and softer (6%) gels, layer by layer shaving was possible with pulse energy rather than number of pulses as the determinant of ultimate cutting depth. The instrument made precise partial or full-thickness cuts of retina, iris, lens, and lens capsule without any evidence of thermal damage. Because different tissues require distinct energies for dissection, tissue-selective cutting on complex structures can be performed if the appropriate pulse energies are used; for example, retina can be dissected without damage to the major retinal vessels.

CONCLUSIONS. This instrument, called the Pulsed Electron Avalanche Knife (PEAK), can quickly and precisely cut intraocular tissues without traction. The small delivery probe and modest cost make it promising for many ophthalmic applications, including retinal, cataract, and glaucoma surgery. In addition, the instrument may be useful in nonophthalmic procedures such as intravascular surgery and neurosurgery.




This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
S. G Priglinger, D. Palanker, C. S Alge, T. C Kreutzer, C. Haritoglou, M. Grueterich, and A. Kampik
Pulsed electron avalanche knife: new technology for cataract surgery
Br. J. Ophthalmol., July 1, 2007; 91(7): 949 - 954.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
T. W. Chalberg, A. Vankov, F. E. Molnar, A. F. Butterwick, P. Huie, M. P. Calos, and D. V. Palanker
Gene transfer to rabbit retina with electron avalanche transfection.
Invest. Ophthalmol. Vis. Sci., September 1, 2006; 47(9): 4083 - 4090.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
S. G. Priglinger, C. Haritoglou, D. V. Palanker, C. S. Alge, A. Gandorfer, and A. Kampik
Pulsed Electron Avalanche Knife (PEAK-fc) for Dissection of Retinal Tissue
Arch Ophthalmol, October 1, 2005; 123(10): 1412 - 1418.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
J. M. Miller, D. V. Palanker, A. Vankov, M. F. Marmor, and M. S. Blumenkranz
Precision and Safety of the Pulsed Electron Avalanche Knife in Vitreoretinal Surgery
Arch Ophthalmol, June 1, 2003; 121(6): 871 - 877.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
D. A. Fletcher, D. V. Palanker, P. Huie, J. Miller, M. F. Marmor, and M. S. Blumenkranz
Intravascular Drug Delivery With a Pulsed Liquid Microjet
Arch Ophthalmol, September 1, 2002; 120(9): 1206 - 1208.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
Daniel. V. Palanker, M. F. Marmor, A. Branco, P. Huie, J. M. Miller, S. R. Sanislo, A. Vankov, and M. S. Blumenkranz
Effects of the Pulsed Electron Avalanche Knife on Retinal Tissue
Arch Ophthalmol, May 1, 2002; 120(5): 636 - 640.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the Association for Research in Vision and Ophthalmology