IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tomic, L.
Right arrow Articles by Alm, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tomic, L.
Right arrow Articles by Alm, A.
(Investigative Ophthalmology and Visual Science. 2001;42:752-755.)
© 2001 by The Association for Research in Vision and Ophthalmology, Inc.

Comparison of Retinal Transit Times and Retinal Blood Flow: A Study in Monkeys

Lidija Tomic1, Olav Mäepea1, Göran O. Sperber2 and Albert Alm1

1 From the Department of Neuroscience, Ophthalmology, and 2 Physiology and Medical Biophysics, Uppsala University, Sweden.

PURPOSE. To determine the correlation between transit times of retinal blood flow calculated from fluorescein angiograms and retinal blood flow determined by the microsphere method.

METHODS. Two fluorescein angiograms were obtained in each eye of six monkeys, followed by determination of retinal blood flow with labeled microspheres. Angiograms in 10 eyes were analyzed for mean transit time (MTT) and arteriovenous passage time (AVP). MTT was determined in two ways: from dye curves reconstructed by extrapolation of semilogarithmic plots of the recorded curves (MTTslope) and by a new technique based on an impulse–response analysis (MTTir).

RESULTS. Mean values (±SD) for retinal blood flow in 10 eyes were 23.2 ± 6.9 mg/min. Corresponding values for MTTir, MTTslope, and AVP were 2.22 ± 0.38, 4.89 ± 5.89, and 1.08 ± 0.14 seconds. There was a weak, but not statistically significant, correlation between retinal blood flow and MTTir (r = -0.60, P = 0.06) but no useful correlation between retinal blood flow and either MTTslope or AVP.

CONCLUSIONS. The relationship between retinal blood flow and transit times determined from fluorescein angiograms is weak. Of the three transit parameters tested, MTTir, determined with the recently developed impulse–response technique, had the best correlation with retinal blood flow. Further studies are needed to determine the ability of these transit parameters to detect a change in retinal blood flow and the possibility that transit times may provide useful clinical information unrelated to absolute values of retinal blood flow.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS