1 From the Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas, Spain; and 2 Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Spain.
PURPOSE. To determine objectively the changes in the ocular aberrations (3rd order and above) induced by myopic LASIK refractive surgery and its impact on image quality.
METHODS. The ocular aberrations of 22 normal myopic eyes (preoperative refraction ranged from -13 to -2 D) were measured before (2.9 ± 4.3 weeks) and after (7.7 ± 3.2 weeks) LASIK refractive surgery using a laser ray tracing technique. A set of laser pencils is sequentially delivered onto the eye through different pupil locations. For each ray, the corresponding retinal image is collected on a CCD camera. The displacement of the image centroid with respect to a reference provides direct information of the ocular aberrations. Root-mean-square (RMS) wavefront error was taken as image quality metric.
RESULTS. RMS wavefront error increased significantly in all eyes but two after surgery. On average, LASIK induced a significant (P = 0.0003) 1.9-fold increase in the RMS error for a 6.5-mm pupil. The main contribution was due to the increase (fourfold, P < 0.0001) of spherical aberration. The increase in the RMS for a 3-mm pupil (1.7-fold) was also significant (P = 0.02). The modulation transfer (computed for 6.5-mm pupil) decreased on average by a factor of 2 for middle-high spatial frequencies.
CONCLUSIONS. (1) Laser ray tracing is a well-suited, robust, and reliable technique for the evaluation of the change of ocular aberrations with refractive surgery. (2) Refractive surgery induces important amounts of 3rd and higher order aberrations. The largest increase occurs for spherical aberration. Decentration of the ablation pattern seems to generate 3rd order aberrations. (3) This result is important for the design of customized ablation algorithms, which should cancel existing preoperative aberrations while avoiding the generation of new aberrations.
This article has been cited by other articles:
![]() |
A. Chan, J. Ou, and E. E. Manche Comparison of the Femtosecond Laser and Mechanical Keratome for Laser In Situ Keratomileusis Arch Ophthalmol, November 1, 2008; 126(11): 1484 - 1490. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Hiraoka, C. Okamoto, Y. Ishii, T. Kakita, and T. Oshika Contrast Sensitivity Function and Ocular Higher-Order Aberrations following Overnight Orthokeratology Invest. Ophthalmol. Vis. Sci., February 1, 2007; 48(2): 550 - 556. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Diaz-Douton, A. Benito, J. Pujol, M. Arjona, J. L. Guell, and P. Artal Comparison of the retinal image quality with a hartmann-shack wavefront sensor and a double-pass instrument. Invest. Ophthalmol. Vis. Sci., April 1, 2006; 47(4): 1710 - 1716. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Smolek and S. D. Klyce Zernike Polynomial Fitting Fails to Represent All Visually Significant Corneal Aberrations Invest. Ophthalmol. Vis. Sci., November 1, 2003; 44(11): 4676 - 4681. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Marcos, S. Barbero, L. Llorente, and J. Merayo-Lloves Optical Response to LASIK Surgery for Myopia from Total and Corneal Aberration Measurements Invest. Ophthalmol. Vis. Sci., December 1, 2001; 42(13): 3349 - 3356. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |