IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moreno-Barriuso, E.
Right arrow Articles by Barbero, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moreno-Barriuso, E.
Right arrow Articles by Barbero, S.
(Investigative Ophthalmology and Visual Science. 2001;42:1396-1403.)
© 2001 by The Association for Research in Vision and Ophthalmology, Inc.

Ocular Aberrations before and after Myopic Corneal Refractive Surgery: LASIK-Induced Changes Measured with Laser Ray Tracing

Esther Moreno-Barriuso1, Jesús Merayo Lloves2, Susana Marcos1, Rafael Navarro1, Lourdes Llorente1 and Sergio Barbero1

1 From the Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas, Spain; and 2 Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Spain.

PURPOSE. To determine objectively the changes in the ocular aberrations (3rd order and above) induced by myopic LASIK refractive surgery and its impact on image quality.

METHODS. The ocular aberrations of 22 normal myopic eyes (preoperative refraction ranged from -13 to -2 D) were measured before (2.9 ± 4.3 weeks) and after (7.7 ± 3.2 weeks) LASIK refractive surgery using a laser ray tracing technique. A set of laser pencils is sequentially delivered onto the eye through different pupil locations. For each ray, the corresponding retinal image is collected on a CCD camera. The displacement of the image centroid with respect to a reference provides direct information of the ocular aberrations. Root-mean-square (RMS) wavefront error was taken as image quality metric.

RESULTS. RMS wavefront error increased significantly in all eyes but two after surgery. On average, LASIK induced a significant (P = 0.0003) 1.9-fold increase in the RMS error for a 6.5-mm pupil. The main contribution was due to the increase (fourfold, P < 0.0001) of spherical aberration. The increase in the RMS for a 3-mm pupil (1.7-fold) was also significant (P = 0.02). The modulation transfer (computed for 6.5-mm pupil) decreased on average by a factor of 2 for middle-high spatial frequencies.

CONCLUSIONS. (1) Laser ray tracing is a well-suited, robust, and reliable technique for the evaluation of the change of ocular aberrations with refractive surgery. (2) Refractive surgery induces important amounts of 3rd and higher order aberrations. The largest increase occurs for spherical aberration. Decentration of the ablation pattern seems to generate 3rd order aberrations. (3) This result is important for the design of customized ablation algorithms, which should cancel existing preoperative aberrations while avoiding the generation of new aberrations.




This article has been cited by other articles:


Home page
IOVSHome page
T. Hiraoka, C. Okamoto, Y. Ishii, T. Kakita, and T. Oshika
Contrast Sensitivity Function and Ocular Higher-Order Aberrations following Overnight Orthokeratology
Invest. Ophthalmol. Vis. Sci., February 1, 2007; 48(2): 550 - 556.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
F. Diaz-Douton, A. Benito, J. Pujol, M. Arjona, J. L. Guell, and P. Artal
Comparison of the retinal image quality with a hartmann-shack wavefront sensor and a double-pass instrument.
Invest. Ophthalmol. Vis. Sci., April 1, 2006; 47(4): 1710 - 1716.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
M. K. Smolek and S. D. Klyce
Zernike Polynomial Fitting Fails to Represent All Visually Significant Corneal Aberrations
Invest. Ophthalmol. Vis. Sci., November 1, 2003; 44(11): 4676 - 4681.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
S. Marcos, S. Barbero, L. Llorente, and J. Merayo-Lloves
Optical Response to LASIK Surgery for Myopia from Total and Corneal Aberration Measurements
Invest. Ophthalmol. Vis. Sci., December 1, 2001; 42(13): 3349 - 3356.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the Association for Research in Vision and Ophthalmology