IOVS The FASEB Journal
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chen, W.-L.
Right arrow Articles by Hung, P.-T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chen, W.-L.
Right arrow Articles by Hung, P.-T.
(Investigative Ophthalmology and Visual Science. 2002;43:3665-3672.)
© 2002 by The Association for Research in Vision and Ophthalmology, Inc.

Ultrasound Biomicroscopic Findings in Rabbit Eyes Undergoing Scleral Suction during Lamellar Refractive Surgery

Wei-Li Chen, Yung-Feng Shih, Shu-Lang Liao, Fung-Rong Hu and Por-Tying Hung

From the Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan.

PURPOSE. To evaluate changes of the central anterior chamber depth, cilio-angular cross-sectional surface area, and intraocular pressure in rabbit eyes undergoing application of the scleral suction ring during lamellar refractive surgery.

METHODS. Thirty eyes of 30 rabbits were used in the study. The eyes were assigned to one of the following five surgical groups: group 1, no application of the suction ring; group 2, suction for 2 minutes; group 3, suction for 1 minute; group 4, suction for 20 seconds; and group 5, suction for 10 seconds. Ultrasound biomicroscopy (UBM) was performed to determine tomographic features, including central anterior chamber depth, cross-sectional surface area of the ciliary body, and chamber angle structure before and 10 minutes, 1 hour, 2 hours, 1 day, 2 days, 1 week, and 2 weeks after surgery. Intraocular pressure was also measured at each of these time points.

RESULTS. Swelling of the ciliary body occurred in groups 2 to 5 of eyes from 10 minutes up to 1 day after the operation, and its severity was positively related to the duration of suction. Shallowness of the chamber angle was positively related to swelling. All UBM-detectable changes became insignificant compared with baseline values at 2 days after the operation. No significant change was found in the central anterior chamber depth and intraocular pressure during the 2-week postoperative observation period.

CONCLUSIONS. Transient change in the ciliary body and the chamber angle occurred frequently after application of the scleral suction ring during lamellar refractive surgery in rabbit eyes. Its severity was positively related to the duration of suction. Swelling of the ciliary body corresponded with the shallowness of the chamber angle without alteration of the corneal–lenticular distance and intraocular pressure.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the Association for Research in Vision and Ophthalmology