IOVS The FASEB Journal
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Anderson, A. J.
Right arrow Articles by Johnson, C. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Anderson, A. J.
Right arrow Articles by Johnson, C. A.
(Investigative Ophthalmology and Visual Science. 2002;43:398-401.)
© 2002 by The Association for Research in Vision and Ophthalmology, Inc.

Mechanisms Isolated by Frequency-Doubling Technology Perimetry

Andrew John Anderson and Chris A. Johnson

From Discoveries in Sight, Devers Eye Institute, Portland Oregon.

Purpose.

The frequency-doubling (FD) phenomenon describes the increase in apparent spatial frequency occurring when low-spatial-frequency sine wave gratings undergo rapid counterphase flicker. It is unclear whether the visual mechanisms isolated when pattern appearance is used as a threshold criterion are the same as when a simple detection criterion (as in FD perimetry) is used. It is also unclear whether the FD stimulus isolates mechanisms that differ from those isolated by spatially uniform flicker. In the current study, adaptation and spatiotemporal tuning functions were determined, using the FD stimulus, uniform flicker, and static (nonflickering) grating targets, to establish whether distinct mechanisms are isolated by the FD stimulus.

METHODS. Spatiotemporal tuning functions were determined in six observers, using an FD stimulus under conditions of detection and resolution and using spatially uniform flickering stimuli and static grating stimuli. The effect of light adaptation on these stimulus classes was also assessed. All stimuli were 10°-wide squares.

RESULTS. Spatiotemporal tuning functions and adaptation characteristics were identical for both the FD detection and resolution paradigms. Spatially uniform flicker gave indistinguishable tuning functions and adaptation characteristics to the FD stimulus at 25 Hz and higher, but differed below this frequency. Static grating stimuli differed from FD stimuli in both tuning functions and adaptation characteristics.

CONCLUSIONS. Absolute detection of the FD stimulus involves mechanisms that are indistinguishable from those involved when a criterion based on spatial form (i.e., resolution of a pattern) is used, indicating that a simple detection criterion can be used in FD perimetry. The FD stimulus isolates similar mechanisms to spatially uniform flickering stimuli at high temporal frequencies.




This article has been cited by other articles:


Home page
IOVSHome page
L. Racette, F. A. Medeiros, L. M. Zangwill, D. Ng, R. N. Weinreb, and P. A. Sample
Diagnostic Accuracy of the Matrix 24-2 and Original N-30 Frequency-Doubling Technology Tests Compared with Standard Automated Perimetry
Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 954 - 960.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
J Landers, A Sharma, I Goldberg, and S Graham
Topography of the frequency doubling perimetry visual field compared with that of short wavelength and achromatic automated perimetry visual fields
Br. J. Ophthalmol., January 1, 2006; 90(1): 70 - 74.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
S. A. Haymes, D. M. Hutchison, T. A. McCormick, D. K. Varma, M. T. Nicolela, R. P. LeBlanc, and B. C. Chauhan
Glaucomatous Visual Field Progression with Frequency-Doubling Technology and Standard Automated Perimetry in a Longitudinal Prospective Study
Invest. Ophthalmol. Vis. Sci., February 1, 2005; 46(2): 547 - 554.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
A Eisner, D F Austin, and J R Samples
Short wavelength automated perimetry and tamoxifen use
Br. J. Ophthalmol., January 1, 2004; 88(1): 125 - 130.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
J. A. Landers, I. Goldberg, and S. L. Graham
Detection of Early Visual Field Loss in Glaucoma Using Frequency-Doubling Perimetry and Short-Wavelength Automated Perimetry
Arch Ophthalmol, December 1, 2003; 121(12): 1705 - 1710.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. J. Anderson and C. A. Johnson
Frequency-Doubling Technology Perimetry and Optical Defocus
Invest. Ophthalmol. Vis. Sci., September 1, 2003; 44(9): 4147 - 4152.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. J. R. White, H. Sun, W. H. Swanson, and B. B. Lee
An Examination of Physiological Mechanisms Underlying the Frequency-Doubling Illusion
Invest. Ophthalmol. Vis. Sci., November 1, 2002; 43(11): 3590 - 3599.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the Association for Research in Vision and Ophthalmology