IOVS Health Education Research
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Turpin, A.
Right arrow Articles by Vingrys, A. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Turpin, A.
Right arrow Articles by Vingrys, A. J.
(Investigative Ophthalmology and Visual Science. 2002;43:709-715.)
© 2002 by The Association for Research in Vision and Ophthalmology, Inc.

Performance of Efficient Test Procedures for Frequency-Doubling Technology Perimetry in Normal and Glaucomatous Eyes

Andrew Turpin1,2, Allison M. McKendrick1,3, Chris A. Johnson1 and Algis J. Vingrys3

From 1 Discoveries in Sight, Devers Eye Institute, Portland, Oregon; the 2 School of Computing, Curtin University of Technology, Perth, Western Australia, Australia; the 3 Department of Psychology, University of Western Australia, Nedlands, Western Australia, Australia; the 4 Department of Optometry and Vision Sciences, University of Melbourne, Melbourne, Victoria, Australia.

PURPOSE. To validate the clinical performance of two new efficient threshold-estimation procedures for frequency-doubling technology (FDT) perimetry in both visually normal individuals and patients with glaucomatous visual field loss.

METHODS. Forty-one normal subjects (mean age, 48.3 ± 11.6 years) and 50 patients with glaucomatous visual field loss (mean age, 72.7 ± 10.0 years) were tested. Some of these participants were retested within a 3-month period. FDT perimetry was performed on a color monitor driven by a visual-stimulus–generating video board, with stimulus parameters designed to closely mimic those of the commercial FDT test. Visual field sensitivity was measured using three procedures: a modified binary search (MOBS) identical with the one used in the commercial FDT device, a rapid efficient binary search (REBS), and a procedure the uses Bayesian methods (zippy estimation of sequential testing; ZEST). The selection of optimum parameters for REBS and ZEST were based on results from previous simulations.

RESULTS. Both ZEST and REBS were 40% to 50% faster than MOBS. All three methods produced similar visual field sensitivity measures, with 95% of the differences occurring between ±2 dB for normal subjects and ±3 dB for glaucoma patients. Test–retest performance was similar for all three procedures.

CONCLUSIONS. The test time for full-threshold FDT perimetry can be approximately halved, by using either the ZEST or REBS procedure, without affecting the accuracy or reliability of the measurements. These findings in normal subjects and patients with glaucoma provide clinical confirmation of our previous investigations of these test strategies that use computer simulation.




This article has been cited by other articles:


Home page
IOVSHome page
L. Racette, F. A. Medeiros, L. M. Zangwill, D. Ng, R. N. Weinreb, and P. A. Sample
Diagnostic Accuracy of the Matrix 24-2 and Original N-30 Frequency-Doubling Technology Tests Compared with Standard Automated Perimetry
Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 954 - 960.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
F. A. Medeiros, P. A. Sample, L. M. Zangwill, J. M. Liebmann, C. A. Girkin, and R. N. Weinreb
A statistical approach to the evaluation of covariate effects on the receiver operating characteristic curves of diagnostic tests in glaucoma.
Invest. Ophthalmol. Vis. Sci., June 1, 2006; 47(6): 2520 - 2527.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. J. Vingrys and A. J. Zele
Robust Indices of Clinical Data: Meaningless Means
Invest. Ophthalmol. Vis. Sci., December 1, 2005; 46(12): 4353 - 4357.
[Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
P G D Spry, H M Hussin, and J M Sparrow
Clinical evaluation of frequency doubling technology perimetry using the Humphrey Matrix 24-2 threshold strategy
Br. J. Ophthalmol., August 1, 2005; 89(8): 1031 - 1035.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
P. H. Artes, D. M. Hutchison, M. T. Nicolela, R. P. LeBlanc, and B. C. Chauhan
Threshold and Variability Properties of Matrix Frequency-Doubling Technology and Standard Automated Perimetry in Glaucoma
Invest. Ophthalmol. Vis. Sci., July 1, 2005; 46(7): 2451 - 2457.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. A. Phipps, T. M. Dang, A. J. Vingrys, and R. H. Guymer
Flicker Perimetry Losses in Age-Related Macular Degeneration
Invest. Ophthalmol. Vis. Sci., September 1, 2004; 45(9): 3355 - 3360.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. Turpin, A. M. McKendrick, C. A. Johnson, and A. J. Vingrys
Properties of Perimetric Threshold Estimates from Full Threshold, ZEST, and SITA-like Strategies, as Determined by Computer Simulation
Invest. Ophthalmol. Vis. Sci., November 1, 2003; 44(11): 4787 - 4795.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. M. McKendrick, A. J. Anderson, C. A. Johnson, and B. Fortune
Appearance of the Frequency Doubling Stimulus in Normal Subjects and Patients with Glaucoma
Invest. Ophthalmol. Vis. Sci., March 1, 2003; 44(3): 1111 - 1116.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the Association for Research in Vision and Ophthalmology