IOVS Annual Reviews: Biomedical Science Suite
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lin, M. C.
Right arrow Articles by Polse, K. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lin, M. C.
Right arrow Articles by Polse, K. A.
(Investigative Ophthalmology and Visual Science. 2002;43:1019-1024.)
© 2002 by The Association for Research in Vision and Ophthalmology, Inc.

Impact of Rigid Gas-Permeable Contact Lens Extended Wear on Corneal Epithelial Barrier Function

Meng C. Lin1, Andrew D. Graham1, Robert E. Fusaro2 and Kenneth A. Polse1

1 From the School of Optometry and the 2 Division of Public Health Biology and Epidemiology, School of Public Health, University of California, Berkeley, California.

PURPOSE. To measure the effect of hypoxia and eye closure on epithelial permeability to fluorescein (Pdc) during rigid lens extended wear (EW).

METHODS. Central corneal thickness (CT) and Pdc were measured in 42 subjects with an optical pachometer and automated scanning fluorophotometer, respectively. All subjects had been successfully wearing rigid gas-permeable (RGP) lenses on a 6-night EW regimen, and each individual was randomized to wear either medium- or high-oxygen-permeable (Dk) RGP lenses (two types of siloxane-fluorocarbon polymer lenses with Dk of 49 and 92). CT and Pdc measurements were performed at an afternoon visit (baseline) and were repeated in the morning after 8 hours of overnight wear. Subjects slept with a patch over the right eye. The patch was not removed until immediately before the morning measurement.

RESULTS. The mean overnight swelling response for subjects in the medium-Dk group was greater than that in the high-Dk group. Results of a paired t-test indicate that the eye wearing the medium-Dk lens with a patch overnight had a significant increase in epithelial permeability. Results of mixed-effect models suggest that eye closure and lens-induced hypoxia are significant factors in altering Pdc.

CONCLUSIONS. The results indicate that corneal epithelial permeability increases with hypoxic dose and that epithelial barrier function is impaired by overnight rigid lens wear.




This article has been cited by other articles:


Home page
IOVSHome page
S. Haque, D. Fonn, T. Simpson, and L. Jones
Epithelial Thickness Changes from the Induction of Myopia with CRTH RGP Contact Lenses
Invest. Ophthalmol. Vis. Sci., August 1, 2008; 49(8): 3345 - 3350.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
S. Teranishi, K. Kimura, K. Kawamoto, and T. Nishida
Protection of Human Corneal Epithelial Cells from Hypoxia-Induced Disruption of Barrier Function by Keratinocyte Growth Factor
Invest. Ophthalmol. Vis. Sci., June 1, 2008; 49(6): 2432 - 2437.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
R. Martin, V. de Juan, G. Rodriguez, R. Cuadrado, and I. Fernandez
Measurement of Corneal Swelling Variations without Removal of the Contact Lens during Extended Wear
Invest. Ophthalmol. Vis. Sci., July 1, 2007; 48(7): 3043 - 3050.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
K. L. Miller, K. A. Polse, and C. J. Radke
Fenestrations Enhance Tear Mixing under Silicone-Hydrogel Contact Lenses
Invest. Ophthalmol. Vis. Sci., January 1, 2003; 44(1): 60 - 67.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the Association for Research in Vision and Ophthalmology