IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fuchsjäger-Mayrl, G.
Right arrow Articles by Schmetterer, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fuchsjäger-Mayrl, G.
Right arrow Articles by Schmetterer, L.
(Investigative Ophthalmology and Visual Science. 2002;43:1520-1524.)
© 2002 by The Association for Research in Vision and Ophthalmology, Inc.

Effects of Granulocyte Colony Stimulating Factor on Retinal Leukocyte and Erythrocyte Flux in the Human Retina

Gabriele Fuchsjäger-Mayrl1, Magdalena Malec1, Elzbieta Polska1, Bernd Jilma1, Michael Wolzt1 and Leopold Schmetterer1,2

1 From the Department of Clinical Pharmacology and the 2 Institute of Medical Physics, Vienna University, Vienna, Austria.

PURPOSE. The blue-field entoptic technique was introduced more than 20 years ago to quantify perimacular white blood cell flux. However, a final confirmation that the perceived corpuscles represent leukocytes is still unavailable.

METHODS. The study design was randomized, placebo-controlled, and double masked with two parallel groups. Fifteen healthy male subjects received a single dose of granulocyte colony stimulating factor (G-CSF, 300 µg) and 15 other subjects received placebo. The following parameters were assessed at baseline and at 12 minutes and 8 hours after administration: retinal white blood cell flux, with the blue-field entoptic technique; retinal blood velocities, with bidirectional laser Doppler velocimetry; retinal venous diameter determined with a retinal vessel analyzer; and blood pressure and pulse rate determined by automated oscillometry and pulse oxymetry, respectively.

RESULTS. After 12 minutes, G-CSF reduced total leukocyte count from 5.5 ± 1.4 109/L at baseline to 1.9 ± 0.4 109/L. This was paralleled by a 35% ± 11% decrease in retinal white blood cell density. After 8 hours G-CSF increased total leukocyte counts to 20.0 ± 4.4 109/L. Again, this increase in circulating leukocytes was reflected by an increase in retinal white blood cell density (110% ± 48%). All effects were significant at P < 0.001. By contrast, none of the other hemodynamic parameters was changed by administration of G-CSF.

CONCLUSIONS. The results clearly indicate that the blue-field entoptic technique assesses leukocyte movement in the perimacular capillaries of the retina. Moreover, white blood cell density appears to adequately reflect the number of circulating leukocytes within the retinal microvasculature. Hence, an increase in retinal white blood cell density does not necessarily reflect retinal vasodilatation.




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. Kolodjaschna, F. Berisha, S. Lung, G. Schaller, E. Polska, B. Jilma, M. Wolzt, and L. Schmetterer
LPS-induced microvascular leukocytosis can be assessed by blue-field entoptic phenomenon
Am J Physiol Heart Circ Physiol, August 1, 2004; 287(2): H691 - H694.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the Association for Research in Vision and Ophthalmology