IOVS Hypertension
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow An erratum has been published
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zeimer, R.
Right arrow Articles by Vitale, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zeimer, R.
Right arrow Articles by Vitale, S.
(Investigative Ophthalmology and Visual Science. 2002;43:1581-1587.)
© 2002 by The Association for Research in Vision and Ophthalmology, Inc.

A Fundus Camera Dedicated to the Screening of Diabetic Retinopathy in the Primary-Care Physician’s Office

Ran Zeimer1, Shazhou Zou2, Torre Meeder2, Kevin Quinn2 and Susan Vitale1

1 From The Johns Hopkins University School of Medicine, Wilmer Ophthalmological Institute, Baltimore, Maryland; and 2 EyeTel Imaging, Inc., Centreville, Virginia.

PURPOSE. To increase the number of diabetic patients being screened for retinopathy, an instrument, the DigiScope, was specifically designed to operate in primary-care physicians’ offices. The DigiScope is described and its automated functions are evaluated.

METHODS. The DigiScope consists of a semiautomated optical head to acquire fundus images, evaluate visual acuity, and transmit the data to a remote reading center through telephone lines. Normal volunteers and 17 consecutive diabetic patients visiting their primary-care physician were recruited, and nonophthalmic staff performed the acquisition session.

RESULTS. The pupil center and working distance were set automatically. Centering was achieved within 750 µm in less than 500 ms. The fundus was successfully focused by an automated algorithm, and an imaging session covering 71° of the posterior pole of both eyes lasted 5.6 ± 2.4 minutes. It was found that a file-compression ratio of 12 did not degrade the clinical information and allowed data transfer in less than 6 minutes. A pilot study in normal eyes showed that the DigiScope images yielded the same amount of details as conventional color fundus photographs obtained by an expert photographer.

CONCLUSIONS. The DigiScope fulfills the instrumental requirements for a practical and cost-effective tool to acquire data needed to identify diabetic patients who must be referred to an eye-care specialist. Widespread screening with the DigiScope may help reduce the risk of vision loss in an estimated 4 million individuals in the United States alone, who currently do not undergo an annual eye examination.




This article has been cited by other articles:


Home page
Diabetes CareHome page
D. S. Fong, L. P. Aiello, F. L. Ferris III, and R. Klein
Diabetic Retinopathy
Diabetes Care, October 1, 2004; 27(10): 2540 - 2553.
[Full Text] [PDF]


Home page
Diabetes CareHome page
A. S. Neubauer, U. C. Welge-Lussen, M. J. Thiel, C. Alge, S. G. Priglinger, C. Hirneiss, M. W. Ulbig, and A. Kampik
Tele-Screening for Diabetic Retinopathy With the Retinal Thickness Analyzer
Diabetes Care, October 1, 2003; 26(10): 2890 - 2897.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
G. P. Leese, A. Ellingford, A. D. Morris, J. D. Ellis, and S. Cunningham
Screening Using Compressed Digital Retinal Images Successfully Identifies Retinopathy
Diabetes Care, January 1, 2003; 26(1): 247 - 247.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the Association for Research in Vision and Ophthalmology