IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tabuchi, H.
Right arrow Articles by Miki, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tabuchi, H.
Right arrow Articles by Miki, T.
(Investigative Ophthalmology and Visual Science. 2002;43:2045-2054.)
© 2002 by The Association for Research in Vision and Ophthalmology, Inc.

Study of the Visual Evoked Magnetic Field with the M-Sequence Technique

Hitoshi Tabuchi1, Tsuranu Yokoyama2, Masahiro Shimogawara3, Kunihiko Shiraki1, Eiichiro Nagasaka4 and Tokuhiko Miki1

1 From the Department of Ophthalmology and Visual Sciences, Osaka City University Graduate School of Medicine, Osaka, Japan; the 2 Department of Pediatric Ophthalmology, Osaka City General Hospital, Osaka, Japan; 3 Applied Electronics Laboratory, Kanazawa Institute of Technology, Kanazawa, Japan; and 4 Mayo Corp., Inazawa, Aichi, Japan.

PURPOSE. Multifocally stimulated visual evoked magnetic field (VEF) examination with an m-sequence technique (multifocal VEF; mVEF) was studied, and the neural generators at peaks of mVEF were estimated in the visual cortex.

METHODS. Visual field stimulation was generated by a multifocal testing system with use of the m-sequence technique. The stimulation pattern covered a central area extending from 0.6° to 10° in radius outward from the center of four visual-field quadrants. The stimulation pattern was projected onto a screen by a liquid crystal projector. VEFs of 14 healthy adults were recorded with a 160-channel, whole-head-type magnetoencephalography (MEG) system. The output signals of 16 selected MEG sensors covering the occipital region were recorded for each subject with the multifocal testing system, and the second-order responses were calculated. The analyzed response data files were transferred to the MEG system, a single equivalent current dipole (ECD) was estimated to locate the neural generator, and the localization was superimposed onto the corresponding brain magnetic resonance image of the subject.

RESULTS. mVEFs showed three peak waves (N75m, P100m, N145m) in 75% of the subjects and two peak waves (N75m, N145m) in 25%. (N, P and m denote negative, positive, and magnetic fields, respectively.) Latencies of the first and the last peak were similar between the two kinds of peak waves. ECD examination showed more than 97% of goodness of fit at all peaks, and the relation between EDCs and the stimulated visual field coincided with a retinotopic organization that fit a cruciform model in all subjects. ECD depths from the occipital pole were similar to the depth expected from the human linear cortical magnification factor model in all subjects. Main neural generators of all mVEF components (N75m, P100m, N145m) were shown in the striate cortex (V1).

CONCLUSIONS. Testing the VEF with an m-sequence technique showed stable responses to simultaneous stimulation of four visual-field quadrants. Consistency of correlation of the estimated ECD with the known cortical organization of the primary visual cortex confirmed the reliability of this examination. The three mVEF peaks were thought to derive mainly from V1 activity.




This article has been cited by other articles:


Home page
IOVSHome page
A. C. James
The Pattern-Pulse Multifocal Visual Evoked Potential
Invest. Ophthalmol. Vis. Sci., February 1, 2003; 44(2): 879 - 890.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the Association for Research in Vision and Ophthalmology