IOVS Molecular Pharmacology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:275-280.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.02-0619

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Findl, O.
Right arrow Articles by Pinz, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Findl, O.
Right arrow Articles by Pinz, A.

Removal of Reflections in the Photographic Assessment of PCO by Fusion of Digital Retroillumination Images

Oliver Findl,1 Wolf Buehl,1 Hannes Siegl,2 and Axel Pinz1

1From the Department of Ophthalmology, University of Vienna, Vienna Austria; and the 2Institute of Electrical Measurement and Measurement Signal Processing, Graz University of Technology, Graz, Austria.

PURPOSE. Automated image-analysis systems for objective assessment of posterior capsule opacification (PCO) depend on good image quality. One major drawback is the existence of light-reflection artifacts (Purkinje spots) in retroillumination images of the posterior capsule. Therefore, a software algorithm was developed that removes these artifacts by fusion of two or more digital images from the same eye, photographed in slightly different directions of gaze.

METHODS. The image-fusion process comprises five steps: definition of a primary and a secondary image, automated segmentation of the region of interest and the Purkinje spots, manual selection of three pairs of corresponding points in both images, geometric registration and radiometric calibration of the regions to be inserted from the secondary image into the primary image. The program was tested with an image set of 30 eyes that had various degrees of PCO. A digital image acquisition system with a coaxial optical path was used to take retroillumination images from each eye in at least three different directions of gaze.

RESULTS. In 28 cases all light-reflection artifacts within the capsulorrhexis rim could be removed entirely. In two cases, small parts of single Purkinje spots remained visible, because the reflections were located too closely in the primary and the secondary images.

CONCLUSIONS. Fusion of digital retroillumination images provides high-quality, reflection-free PCO images. This allows objective PCO assessment systems to analyze 100% of the posterior capsule, leading to more accurate results.





This article has been cited by other articles:


Home page
IOVSHome page
D. Grewal, R. Jain, G. S. Brar, and S. P. S. Grewal
Pentacam Tomograms: A Novel Method for Quantification of Posterior Capsule Opacification
Invest. Ophthalmol. Vis. Sci., May 1, 2008; 49(5): 2004 - 2008.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology