IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:68-77.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.02-0377

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nichols, J. J.
Right arrow Articles by King-Smith, P. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nichols, J. J.
Right arrow Articles by King-Smith, P. E.

Thickness of the Pre- and Post–Contact Lens Tear Film Measured In Vivo by Interferometry

Jason J. Nichols and P. Ewen King-Smith

From The Ohio State University College of Optometry, Columbus, Ohio.

PURPOSE. To evaluate an interferometric method for measuring the thickness of the pre- (PLTF) and postlens tear film (POLTF) in subjects wearing hydrogel contact lenses. The precision and accuracy of measuring postlens tear thickness is compared with a previous method based on optical pachymetry and mechanical measurement of contact lens thickness.

METHODS. Reflectance spectra (562–1030 nm) from the front of an eye wearing a contact lens were measured at normal incidence. Interference between reflections from four surfaces—the front of the tear film, the front and back of the contact lens, and the front of the cornea—can give rise to as many as six oscillations in the reflectance spectra, three from simple layers (layer A: PLTF; B, POLTF; C, contact lens) and three from composite layers, (layer D, A+C; layer E, C+B; layer F, A+C+B). The thickness of any layer is derived from the frequency of the oscillations. The principle of the method was tested with a rigid contact lens, which was designed to give distinct thicknesses for all six layers. Twenty spectra were then recorded from each of 12 subjects wearing hydrogel contact lenses.

RESULTS. The PLTF thickness averaged 2.31 µm. There was good agreement between a direct estimate from layer A and an indirect estimate: layer D minus layer C. For POLTF, an indirect estimate—layer F minus layer D—averaged 2.34 µm and was more satisfactory than the direct estimate from layer B. There was no correlation between PLTF and POLTF thickness, showing that these are independent measurements, despite the similarity of their means.

CONCLUSIONS. Prelens tear thickness was in reasonable agreement with prior measurements. Postlens tear thickness was much less than the 11 to 12 µm found by the pachymetric method. It is argued that the current method avoids some of the systematic errors of the pachymetric method and also has much higher precision.





This article has been cited by other articles:


Home page
IOVSHome page
J. J. Nichols and L. T. Sinnott
Tear film, contact lens, and patient-related factors associated with contact lens-related dry eye.
Invest. Ophthalmol. Vis. Sci., April 1, 2006; 47(4): 1319 - 1328.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
H. Saaren-Seppala, M. Jauhiainen, T. M. T. Tervo, B. Redl, P. K. J. Kinnunen, and J. M. Holopainen
Interaction of Purified Tear Lipocalin with Lipid Membranes
Invest. Ophthalmol. Vis. Sci., October 1, 2005; 46(10): 3649 - 3656.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. J. Nichols, G. L. Mitchell, and P. E. King-Smith
Thinning Rate of the Precorneal and Prelens Tear Films
Invest. Ophthalmol. Vis. Sci., July 1, 2005; 46(7): 2353 - 2361.
[Abstract] [Full Text] [PDF]


Home page
Occup. Environ. Med.Home page
P Wolkoff, J K Nojgaard, P Troiano, and B Piccoli
Eye complaints in the office environment: precorneal tear film integrity influenced by eye blinking efficiency
Occup. Environ. Med., January 1, 2005; 62(1): 4 - 12.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. J. Nichols and P. E. King-Smith
The Impact of Hydrogel Lens Settling on the Thickness of the Tears and Contact Lens
Invest. Ophthalmol. Vis. Sci., August 1, 2004; 45(8): 2549 - 2554.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
K. Maruyama, N. Yokoi, A. Takamata, and S. Kinoshita
Effect of Environmental Conditions on Tear Dynamics in Soft Contact Lens Wearers
Invest. Ophthalmol. Vis. Sci., August 1, 2004; 45(8): 2563 - 2568.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology