From The Ohio State University College of Optometry, Columbus, Ohio.
PURPOSE. To evaluate an interferometric method for measuring the thickness of the pre- (PLTF) and postlens tear film (POLTF) in subjects wearing hydrogel contact lenses. The precision and accuracy of measuring postlens tear thickness is compared with a previous method based on optical pachymetry and mechanical measurement of contact lens thickness.
METHODS. Reflectance spectra (5621030 nm) from the front of an eye wearing a contact lens were measured at normal incidence. Interference between reflections from four surfacesthe front of the tear film, the front and back of the contact lens, and the front of the corneacan give rise to as many as six oscillations in the reflectance spectra, three from simple layers (layer A: PLTF; B, POLTF; C, contact lens) and three from composite layers, (layer D, A+C; layer E, C+B; layer F, A+C+B). The thickness of any layer is derived from the frequency of the oscillations. The principle of the method was tested with a rigid contact lens, which was designed to give distinct thicknesses for all six layers. Twenty spectra were then recorded from each of 12 subjects wearing hydrogel contact lenses.
RESULTS. The PLTF thickness averaged 2.31 µm. There was good agreement between a direct estimate from layer A and an indirect estimate: layer D minus layer C. For POLTF, an indirect estimatelayer F minus layer Daveraged 2.34 µm and was more satisfactory than the direct estimate from layer B. There was no correlation between PLTF and POLTF thickness, showing that these are independent measurements, despite the similarity of their means.
CONCLUSIONS. Prelens tear thickness was in reasonable agreement with prior measurements. Postlens tear thickness was much less than the 11 to 12 µm found by the pachymetric method. It is argued that the current method avoids some of the systematic errors of the pachymetric method and also has much higher precision.
This article has been cited by other articles:
![]() |
J. J. Nichols and L. T. Sinnott Tear film, contact lens, and patient-related factors associated with contact lens-related dry eye. Invest. Ophthalmol. Vis. Sci., April 1, 2006; 47(4): 1319 - 1328. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Saaren-Seppala, M. Jauhiainen, T. M. T. Tervo, B. Redl, P. K. J. Kinnunen, and J. M. Holopainen Interaction of Purified Tear Lipocalin with Lipid Membranes Invest. Ophthalmol. Vis. Sci., October 1, 2005; 46(10): 3649 - 3656. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Nichols, G. L. Mitchell, and P. E. King-Smith Thinning Rate of the Precorneal and Prelens Tear Films Invest. Ophthalmol. Vis. Sci., July 1, 2005; 46(7): 2353 - 2361. [Abstract] [Full Text] [PDF] |
||||
![]() |
P Wolkoff, J K Nojgaard, P Troiano, and B Piccoli Eye complaints in the office environment: precorneal tear film integrity influenced by eye blinking efficiency Occup. Environ. Med., January 1, 2005; 62(1): 4 - 12. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Nichols and P. E. King-Smith The Impact of Hydrogel Lens Settling on the Thickness of the Tears and Contact Lens Invest. Ophthalmol. Vis. Sci., August 1, 2004; 45(8): 2549 - 2554. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Maruyama, N. Yokoi, A. Takamata, and S. Kinoshita Effect of Environmental Conditions on Tear Dynamics in Soft Contact Lens Wearers Invest. Ophthalmol. Vis. Sci., August 1, 2004; 45(8): 2563 - 2568. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |