IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:4676-4681.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.03-0190

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smolek, M. K.
Right arrow Articles by Klyce, S. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smolek, M. K.
Right arrow Articles by Klyce, S. D.

Zernike Polynomial Fitting Fails to Represent All Visually Significant Corneal Aberrations

Michael K. Smolek and Stephen D. Klyce

From the LSU Eye Center, Louisiana State University Health Sciences Center, School of Medicine, New Orleans, Louisiana.

PURPOSE. It is assumed that wavefront error data arising from aberrometry are adequately described by a Zernike polynomial function, although this assumption has not been extensively tested. Inaccuracies in wavefront error may compromise clinical testing and refractive correction procedures. The current retrospective study correlates visual acuity with corneal wavefront error and with the residual surface elevation error after fitting with the Zernike method.

METHODS. Corneal topography maps were obtained from 32 keratoconus cases, 27 postoperative penetrating keratoplasty cases, and 29 postoperative conductive keratoplasty cases (88 total). The best spectacle-corrected visual acuity (BSCVA) for each case ranged from -0.2 to 1.3 logarithm of the minimum angle of resolution (logMAR) units (20/12.5–20/400). Topography was analyzed to determine wavefront error and the elevation fit error for a 4-mm optical zone. The 4th and 10th expansion series were analyzed with the 0th-order (piston) and 1st order (tip and tilt) removed. Linear regression analysis was performed. The difference in root mean square (RMS) error between the 4th- and 10th-order analyses was assessed for both wavefront and elevation fit error.

RESULTS. The correlation of BSCVA to wavefront error for 4th-order terms was moderately strong and significant (R2 = 0.581; P < 0.001). The 10th-order correlation for wavefront error had a similar result (R2 = 0.565; P < 0.001), but the regression was not significantly different from the 4th-order result. The correlation of BSCVA to the elevation fit error was strong and significant for the 4th order (R2 = 0.658; P < 0.001). The 10th-order data had a similar result (R2 = 0.509; P < 0.001), and there was no significant difference between the two regressions. Only 72% of the cases showed a shift toward increased wavefront error with the 10th-order series, whereas 18% lost wavefront error. All cases showed a shift toward improved elevation fit with the 10th-order expansion.

CONCLUSIONS. The wavefront error correlation to acuity was moderately strong, but the corneal elevation fit error also strongly correlated with visual acuity, indicating that Zernike polynomials do not fully characterize the surface shape features that influence vision and that exist in postsurgical or pathologic eyes. In addition, the change in wavefront error when using a larger expansion series was found to increase or diminish somewhat unpredictably. The authors conclude that Zernike polynomials fail to model all the information that influences visual acuity, which may confound clinical diagnosis and treatment.





This article has been cited by other articles:


Home page
IOVSHome page
R. Kosaki, N. Maeda, K. Bessho, Y. Hori, K. Nishida, A. Suzaki, Y. Hirohara, T. Mihashi, T. Fujikado, and Y. Tano
Magnitude and Orientation of Zernike Terms in Patients with Keratoconus
Invest. Ophthalmol. Vis. Sci., July 1, 2007; 48(7): 3062 - 3068.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. Tabernero, S. D. Klyce, E. J. Sarver, and P. Artal
Functional Optical Zone of the Cornea
Invest. Ophthalmol. Vis. Sci., March 1, 2007; 48(3): 1053 - 1060.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
L. A. Carvalho
Accuracy of Zernike Polynomials in Characterizing Optical Aberrations and the Corneal Surface of the Eye
Invest. Ophthalmol. Vis. Sci., June 1, 2005; 46(6): 1915 - 1926.
[Abstract] [Full Text] [PDF]

eLetters:

Read all eLetters

Inadequacy of Zernike Polynomial Fitting: Case Not Made
Charles E. Campbell
IOVS Online, 27 Feb 2004 [Full text]
Author Response: Inadequacy of Zernike Polynomial Fitting: Case Not Made
Michael K. Smolek, et al.
IOVS Online, 27 Feb 2004 [Full text]



HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology