IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:4742-4746.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.03-0239

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wang, J.
Right arrow Articles by Jones, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wang, J.
Right arrow Articles by Jones, L.

Topographical Thickness of the Epithelium and Total Cornea after Overnight Wear of Reverse-Geometry Rigid Contact Lenses for Myopia Reduction

Jianhua Wang,1,2 Desmond Fonn,1 Trefford L. Simpson,1 Luigina Sorbara,1 Richard Kort,1 and Lyndon Jones1

1From the Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada.

PURPOSE. To investigate topographical thickness changes of the epithelium and total cornea measured with optical coherence tomography (OCT) after overnight wear of rigid gas-permeable lenses.

METHODS. Reverse geometry design CRT (Dk = 100) rigid (test) lenses (Paragon Vision Sciences, Mesa, AZ) were randomly fitted on one eye of each of 20 neophyte subjects (mean age, 24.6 ± 2.7 years) and the other eye was fitted with an alignment tricurve rigid lens of the same material (control). Epithelial and total corneal thickness was measured at intervals of 10° across a 10-mm zone of the horizontal meridian of the cornea, before and after overnight wear. Refractive error was measured with an autorefractor. These measurements were repeated 20 and 60 minutes and 3, 6, and 12 hours after lens removal.

RESULTS. After one night of lens wear, myopia decreased in the test eye by 1.18 ± 0.81 D, which was significantly different from baseline (P < 0.001). No significant change was found in the control eye. Twelve hours after removal, two thirds of the myopic reduction was still present. Different topographical swelling patterns were induced by the two lens designs, with greatest swelling occurring in the center with the control lens and in the midperiphery with the test lenses (polynomial regression: P < 0.005). Significantly greater central corneal swelling was found with the control lens than the test lens (6.9% ± 3.1% vs. 4.9% ± 2.0%, respectively, P = 0.006). The effect on epithelial thickness differed between lenses and depended on both position and time (F(48,912) = 2.3; P = 0.000). Immediately after removal of the test lens, the central epithelium was 5.1% ± 4.5% thinner than baseline, and all other locations (P < 0.005 post hoc tests) and the epithelium in the midperiphery showed significant thickening (1.9% on the temporal side and 2.4% on the nasal side, both P < 0.006 compared with the baseline). There were no significant changes in epithelial thickness with the control lens during the study period (post hoc tests: P > 0.05).

CONCLUSIONS. The optical coherence tomograph is a sensitive instrument that can detect small changes in epithelial and corneal thickness across the entire cornea. Topographical thickness changes of the epithelium and total cornea induced by one night of reverse-geometry lens wear appear to be associated with the decrease of myopia.





This article has been cited by other articles:


Home page
IOVSHome page
S. Haque, D. Fonn, T. Simpson, and L. Jones
Epithelial Thickness Changes from the Induction of Myopia with CRTH RGP Contact Lenses
Invest. Ophthalmol. Vis. Sci., August 1, 2008; 49(8): 3345 - 3350.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. Wang, J. Aquavella, J. Palakuru, S. Chung, and C. Feng
Relationships between Central Tear Film Thickness and Tear Menisci of the Upper and Lower Eyelids.
Invest. Ophthalmol. Vis. Sci., October 1, 2006; 47(10): 4349 - 4355.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. Wang, J. Aquavella, J. Palakuru, and S. Chung
Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears.
Invest. Ophthalmol. Vis. Sci., August 1, 2006; 47(8): 3325 - 3329.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. Alharbi, D. La Hood, and H. A. Swarbrick
Overnight Orthokeratology Lens Wear Can Inhibit the Central Stromal Edema Response
Invest. Ophthalmol. Vis. Sci., July 1, 2005; 46(7): 2334 - 2340.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. Wang, T. L. Simpson, and D. Fonn
Objective Measurements of Corneal Light-Backscatter during Corneal Swelling, by Optical Coherence Tomography
Invest. Ophthalmol. Vis. Sci., October 1, 2004; 45(10): 3493 - 3498.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology