IOVS Journal of Neurophysiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:497-504.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.02-0070

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Anker, S.
Right arrow Articles by Wade, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Anker, S.
Right arrow Articles by Wade, J.

Identification of Infants with Significant Refractive Error and Strabismus in a Population Screening Program using Noncycloplegic Videorefraction and Orthoptic Examination

Shirley Anker,1 Janette Atkinson,1 Oliver Braddick,1,2 David Ehrlich,1,3 Thomas Hartley,1 Marko Nardini,1 and Jacqueline Wade1,4

1From the Visual Development Unit, Department of Psychology, University College London, London, United Kingdom; and the 4Ophthalmic Department, Addenbrooke’s Hospital, Cambridge, United Kingdom.

PURPOSE. The second Cambridge Infant Vision Screening Program examined whether screening for accommodative errors by using videorefraction without cycloplegia could effectively serve as a first stage of screening for refractive errors, measured by standard cycloplegic retinoscopy. The screening also included an orthoptic examination for detection of strabismus.

METHODS. All infants born in the Cambridge (UK) Health District, over a 2-year period, were invited for screening. Of those 5142 (76%) with mean age 8.1 ± 0.8 months (SD) attended and received noncycloplegic videorefraction and an orthoptic examination. All those with a focusing error or orthoptic problem, as well as a randomly selected sample of visually normal control subjects, were invited to follow-up a month later for cycloplegic retinoscopy, repeat noncycloplegic videorefraction and orthoptic examination.

RESULTS. Of the 5142 screened, 514 had a focusing error or orthoptic problem (positives). Four hundred thirty-nine of these and 284 visually normal control subjects (negatives) attended follow-up. A refractive or orthoptic condition was confirmed in 59.0% of the positive cases, whereas infants in 96.8% of the negative cases were confirmed normal. Adjusting for the proportions of the population represented by those infants seen at follow-up, sensitivity for the screening procedure was calculated at 0.67 and specificity at 0.96. Detailed results are presented in terms of the different conditions detected at screening (far, near, and anisometropic focus and orthoptic error), distribution of greatest axes at screening, and a comparison of initial videorefraction with repeat videorefraction and cycloplegic retinoscopy.

CONCLUSIONS. A noncycloplegic screening procedure, simpler to perform than cycloplegic screening, succeeded in detecting a large proportion of infants with significant ametropia, particularly those with significant hyperopia, which is considered to be a strabismogenic and amblyogenic risk factor.





This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
M J Moseley and A R Fielder
Preschool vision screening
Br. J. Ophthalmol., August 1, 2003; 87(8): 931 - 931.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology