IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:529-532.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.02-0003

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Feng, Y.
Right arrow Articles by Simpson, T. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Feng, Y.
Right arrow Articles by Simpson, T. L.

Nociceptive Sensation and Sensitivity Evoked from Human Cornea and Conjunctiva Stimulated by CO2

Yunwei Feng and Trefford L. Simpson

From the School of Optometry, University of Waterloo, Waterloo, Ontario, Canada.

PURPOSE. To compare sensation and sensitivity evoked from human cornea and conjunctiva stimulated by CO2.

METHODS. Twenty healthy participants were recruited for the study. Central corneal and temporal conjunctival chemical sensation and sensitivity of only one eye of each subject were evaluated. Air mixed with different concentrations of CO2 was delivered by a modified Belmonte pneumatic esthesiometer. The ascending method of limits was used to determine the sensitivity and subjects were required to characterize the sensation at threshold.

RESULTS. The sensations evoked by CO2 in the cornea and conjunctiva were stinging or burning. The sensation evoked by mechanical stimulation was that of irritation. The corneal and conjunctival chemical thresholds were 31% ± 2% and 54% ± 5% CO2 (mean ± SE), respectively. The corneal and conjunctival mechanical thresholds were 80 ± 6 and 140 ± 10 mL/min (mean ± SE), respectively. The corneal sensitivity was significantly higher for both mechanical and chemical stimuli (P < 0.05).

CONCLUSIONS. The results suggest that CO2 stimulates similar corneal and conjunctival nociceptors in that the interpretations were the same (i.e., nociceptive). The central cornea had a higher sensitivity to CO2 than the temporal conjunctiva, which may reflect a different peripheral innervation, such as different nerve density or different receptor characteristics. Sensations evoked by mechanical and chemical stimulation were different, which suggests that at the peripheral level, the two modalities stimulate two different kinds of molecular receptors or channels and that this information is somehow retained within the nociceptive system.





This article has been cited by other articles:


Home page
IOVSHome page
Y. Feng and T. L. Simpson
The Inhibitory Interaction between Human Corneal and Conjunctival Sensory Channels
Invest. Ophthalmol. Vis. Sci., April 1, 2005; 46(4): 1251 - 1255.
[Abstract] [Full Text] [PDF]


Home page
Occup. Environ. Med.Home page
P Wolkoff, J K Nojgaard, P Troiano, and B Piccoli
Eye complaints in the office environment: precorneal tear film integrity influenced by eye blinking efficiency
Occup. Environ. Med., January 1, 2005; 62(1): 4 - 12.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
F Stapleton, M E Tan, E B Papas, K Ehrmann, B Golebiowski, J Vega, and B A Holden
Corneal and conjunctival sensitivity to air stimuli
Br. J. Ophthalmol., December 1, 2004; 88(12): 1547 - 1551.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
Y. Feng and T. L. Simpson
Characteristics of Human Corneal Psychophysical Channels
Invest. Ophthalmol. Vis. Sci., September 1, 2004; 45(9): 3005 - 3010.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
P. J. Murphy, S. Patel, N. Kong, R. E. J. Ryder, and J. Marshall
Noninvasive Assessment of Corneal Sensitivity in Young and Elderly Diabetic and Nondiabetic Subjects
Invest. Ophthalmol. Vis. Sci., June 1, 2004; 45(6): 1737 - 1742.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology