IOVS Stroke
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:740-744.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.02-0375

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Okabe, J.
Right arrow Articles by Ogura, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Okabe, J.
Right arrow Articles by Ogura, Y.

Biodegradable Intrascleral Implant for Sustained Intraocular Delivery of Betamethasone Phosphate

Junko Okabe, Hideya Kimura, Noriyuki Kunou, Komei Okabe, Aki Kato, and Yuichiro Ogura

From the Department of Ophthalmology, Nagoya City University Medical School, Nagoya, Japan.

PURPOSE. To evaluate the feasibility of using a biodegradable intrascleral implant for intraocular sustained delivery of betamethasone phosphate (BP).

METHODS. The intrascleral implant (0.5 mm thick and 4 mm in diameter) was made of poly(DL-lactide) containing 25% betamethasone phosphate. The in vitro release of BP from the implant was evaluated by high-performance liquid chromatography (HPLC). The implants were placed into a scleral pocket in the rabbit’s eye. The concentrations of BP in the aqueous humor, vitreous, and retina-choroid were measured by HPLC. The toxicity and biocompatibility of the implant were evaluated by slit lamp examination, electroretinography, and light microscopy.

RESULTS. In vitro studies demonstrated that the implants released BP in a biphasic pattern for at least 8 weeks. The BP concentrations in the vitreous and the retina-choroid remained within the concentration range capable of suppressing inflammatory responses for more than 8 weeks. The BP concentration was greater in the retina-choroid than in the vitreous. In the aqueous humor, BP was below the detection limit during the observation period. No significant toxicity to the retina was observed. Also, the implant showed good biocompatibility in the eye.

CONCLUSIONS. These results suggest that the intrascleral implant would be a promising system for delivery of steroid to the posterior segment of the eye.





This article has been cited by other articles:


Home page
IOVSHome page
A. Silva-Cunha, S. L. Fialho, M.-C. Naud, and F. Behar-Cohen
Poly-{epsilon}-Caprolactone Intravitreous Devices: An In Vivo Study
Invest. Ophthalmol. Vis. Sci., May 1, 2009; 50(5): 2312 - 2318.
[Abstract] [Full Text] [PDF]


Home page
Toxicol PatholHome page
B. G. Short
Safety Evaluation of Ocular Drug Delivery Formulations: Techniques and Practical Considerations
Toxicol Pathol, January 1, 2008; 36(1): 49 - 62.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
S. H. Kim, C. J. Galban, R. J. Lutz, R. L. Dedrick, K. G. Csaky, M. J. Lizak, N. S. Wang, G. Tansey, and M. R. Robinson
Assessment of Subconjunctival and Intrascleral Drug Delivery to the Posterior Segment Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging
Invest. Ophthalmol. Vis. Sci., February 1, 2007; 48(2): 808 - 814.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
B. C. Gilger, J. H. Salmon, D. A. Wilkie, L. P. J. Cruysberg, J. Kim, M. Hayat, H. Kim, S. Kim, P. Yuan, S. S. Lee, et al.
A novel bioerodible deep scleral lamellar cyclosporine implant for uveitis.
Invest. Ophthalmol. Vis. Sci., June 1, 2006; 47(6): 2596 - 2605.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
K. Okabe, H. Kimura, J. Okabe, A. Kato, H. Shimizu, T. Ueda, S. Shimada, and Y. Ogura
Effect of Benzalkonium Chloride on Transscleral Drug Delivery
Invest. Ophthalmol. Vis. Sci., February 1, 2005; 46(2): 703 - 708.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. Kato, H. Kimura, K. Okabe, J. Okabe, N. Kunou, and Y. Ogura
Feasibility of Drug Delivery to the Posterior Pole of the Rabbit Eye with an Episcleral Implant
Invest. Ophthalmol. Vis. Sci., January 1, 2004; 45(1): 238 - 244.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
K. Okabe, H. Kimura, J. Okabe, A. Kato, N. Kunou, and Y. Ogura
Intraocular Tissue Distribution of Betamethasone after Intrascleral Administration Using a Non-biodegradable Sustained Drug Delivery Device
Invest. Ophthalmol. Vis. Sci., June 1, 2003; 44(6): 2702 - 2707.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology