IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:1388-1394.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
doi:10.1167/iovs.02-0169

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bengtsson, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bengtsson, B.

A New Rapid Threshold Algorithm for Short-Wavelength Automated Perimetry

Boel Bengtsson

From the Department of Ophthalmology, Malmö University Hospital, Malmö, Sweden.

PURPOSE. To develop and test a short and reliable visual field threshold program for the early detection of glaucomatous visual field loss, by adapting the Swedish interactive test algorithm (SITA) to short-wavelength-automated-perimetry (SWAP).

METHODS. Computer simulations were performed to test the accuracy of several versions of SITA SWAP, and to optimize speed versus reliability. The selected SITA SWAP version was evaluated and compared with the older Full Threshold SWAP and Fastpac SWAP programs in 41 patients with glaucoma and normal subjects.

RESULTS. Average test time was 3.6 minutes for SITA SWAP, 11.8 minutes for Full Threshold SWAP, and 7.7 minutes for Fastpac SWAP, differences were significant at P < 0.0001. Mean threshold reproducibility, calculated as absolute difference between two tests, did not differ significantly between programs and was 2.4 dB for SITA, 2.3 dB for Full Threshold, and 2.4 dB for Fastpac SWAP. Simultaneous comparison showed significant differences in threshold sensitivity, P = 0.023: SITA SWAP showed highest sensitivity, 21.6 dB on average, compared with both Full Threshold SWAP and Fastpac SWAP with a mean sensitivity of 17.3 and 17.8 dB, respectively.

CONCLUSIONS. SITA SWAP was much faster than the older SWAP strategies, and reproducibility did not differ. This implies that SITA SWAP could become a clinically useful method for the detection of early glaucoma. SWAP tests may also be applicable in larger groups of patients because of the increased dynamic range.





This article has been cited by other articles:


Home page
IOVSHome page
M. Ng, L. Racette, J. P. Pascual, J. M. Liebmann, C. A. Girkin, S. L. Lovell, L. M. Zangwill, R. N. Weinreb, and P. A. Sample
Comparing the Full-Threshold and Swedish Interactive Thresholding Algorithms for Short-Wavelength Automated Perimetry
Invest. Ophthalmol. Vis. Sci., April 1, 2009; 50(4): 1726 - 1733.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. Tafreshi, P. A. Sample, J. M. Liebmann, C. A. Girkin, L. M. Zangwill, R. N. Weinreb, M. Lalezary, and L. Racette
Visual Function-Specific Perimetry to Identify Glaucomatous Visual Loss Using Three Different Definitions of Visual Field Abnormality
Invest. Ophthalmol. Vis. Sci., March 1, 2009; 50(3): 1234 - 1240.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. Turpin, D. Jankovic, and A. M. McKendrick
Retesting Visual Fields: Utilizing Prior Information to Decrease Test-Retest Variability in Glaucoma
Invest. Ophthalmol. Vis. Sci., April 1, 2007; 48(4): 1627 - 1634.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. J. Anderson and A. M. McKendrick
Quantifying Adaptation and Fatigue Effects in Frequency Doubling Perimetry
Invest. Ophthalmol. Vis. Sci., February 1, 2007; 48(2): 943 - 948.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. J. Anderson and C. A. Johnson
Anatomy of a Supergroup: Does a Criterion of Normal Perimetric Performance Generate a Supernormal Population?
Invest. Ophthalmol. Vis. Sci., November 1, 2003; 44(11): 5043 - 5048.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology