IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:1962-1968.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.02-0828

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Anderson, A. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Anderson, A. J.

Spatial Resolution of the Tendency-Oriented Perimetry Algorithm

Andrew J. Anderson

From Discoveries in Sight, Devers Eye Institute, Portland Oregon.

PURPOSE. Tendency-oriented perimetry (TOP) is a new strategy designed to estimate the sensitivity of the visual field quickly, by using linear interpolation between test locations. This study determined the spatial resolution characteristics of TOP.

METHODS. A Monte-Carlo technique was used to simulate visual fields, and incorporated realistic amounts of subject response variability as well as variability in the average sensitivity of the field. Visual field defects of various depths, ranging from a single point through to 18 contiguous points, were added to the simulated fields. An estimate of the visual field was made using the TOP algorithm. Global indices (mean deviation [MD] and loss variance [LV]) were calculated for both the true visual field and the TOP estimate.

RESULTS. For small defects of one or two points, the TOP algorithm typically overestimated sensitivity. Sensitivity estimates tended to stratify into one of two possible values, with the lower value being dependent on the absolute position of the defect within the visual field. Although MD was satisfactorily predicted by TOP, LV was underestimated and reached a plateau when defects were deep, especially with smaller defects. For relatively large defects of nine contiguous points, both defect depth and LV was predicted with reasonable accuracy by TOP. The TOP sensitivity estimate for normal locations surrounding a defect was systematically reduced.

CONCLUSIONS. The TOP procedure has a number of unusual spatial characteristics that prevent it from accurately estimating the spatial extent and absolute sensitivity of visual field defects.





eLetters:

Read all eLetters

The A. J. Anderson TOP Algorithm Simulation
Manuel A. González de la Rosa
IOVS Online, 6 Aug 2003 [Full text]
Author Response: The A. J. Anderson TOP Algorithm Simulation
Andrew J. Anderson
IOVS Online, 6 Aug 2003 [Full text]



HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology