IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:2606-2612.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.02-0814

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Medeiros, F. A.
Right arrow Articles by Weinreb, R. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Medeiros, F. A.
Right arrow Articles by Weinreb, R. N.

Fourier Analysis of Scanning Laser Polarimetry Measurements with Variable Corneal Compensation in Glaucoma

Felipe A. Medeiros, Linda M. Zangwill, Christopher Bowd, Antje S. Bernd, and Robert N. Weinreb

From the Hamilton Glaucoma Center and Diagnostic Imaging Laboratory, Department of Ophthalmology, University of California, San Diego, California.

PURPOSE. To apply Fourier analysis to the retinal nerve fiber layer (RNFL) thickness measurements obtained with scanning laser polarimetry (SLP), by using variable corneal compensation, and to evaluate the ability of this method to discriminate glaucomatous from normal eyes.

METHODS. The study included one eye each of 55 patients with glaucoma and 52 healthy subjects. RNFL thickness measurements were obtained with a modified commercial scanning laser polarimeter (GDx Nerve Fiber Analyzer; Laser Diagnostic Technologies, Inc., San Diego, CA) so that corneal birefringence could be corrected on a subject-specific variable basis. The shape of the RNFL thickness double-hump pattern was analyzed by Fourier analysis of polarimetry data. Fourier coefficients and GDx parameters were compared between the two groups. A linear discriminant function was developed to identify and combine the most useful Fourier coefficients to separate the two groups. Receiver operating characteristic (ROC) curves were obtained for each measurement, and sensitivity values (at fixed specificities) were calculated.

RESULTS. The Fourier-based linear discriminant function (LDF Fourier) resulted in a sensitivity of 84% for a specificity set at 92%. For similar specificity, the GDx software–provided parameters had sensitivities ranging from 24% to 69%. The area under ROC curve for the LDF Fourier was 0.949, significantly larger than the ROC curve area for the single best GDx software–provided parameter, superior average (0.870).

CONCLUSIONS. The combination of Fourier RNFL thickness measures in an LDF, obtained using SLP with variable corneal compensation, improved the ability to discriminate glaucomatous from healthy eyes, compared with the GDx software–provided parameters.





This article has been cited by other articles:


Home page
IOVSHome page
C. Bowd, J. Hao, I. M. Tavares, F. A. Medeiros, L. M. Zangwill, T.-W. Lee, P. A. Sample, R. N. Weinreb, and M. H. Goldbaum
Bayesian Machine Learning Classifiers for Combining Structural and Functional Measurements to Classify Healthy and Glaucomatous Eyes
Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 945 - 953.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
F. A. Medeiros, C. Bowd, L. M. Zangwill, C. Patel, and R. N. Weinreb
Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation
Invest. Ophthalmol. Vis. Sci., July 1, 2007; 48(7): 3146 - 3153.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
C. K.-s. Leung, W.-m. Chan, K. K.-L. Chong, W.-h. Yung, K.-t. Tang, J. Woo, W.-m. Chan, and K.-k. Tse
Comparative Study of Retinal Nerve Fiber Layer Measurement by StratusOCT and GDx VCC, I: Correlation Analysis in Glaucoma
Invest. Ophthalmol. Vis. Sci., September 1, 2005; 46(9): 3214 - 3220.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
E. A. Essock, Y. Zheng, and P. Gunvant
Analysis of GDx-VCC Polarimetry Data by Wavelet-Fourier Analysis across Glaucoma Stages
Invest. Ophthalmol. Vis. Sci., August 1, 2005; 46(8): 2838 - 2847.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
L. M. Zangwill, K. Chan, C. Bowd, J. Hao, T.-W. Lee, R. N. Weinreb, T. J. Sejnowski, and M. H. Goldbaum
Heidelberg Retina Tomograph Measurements of the Optic Disc and Parapapillary Retina for Detecting Glaucoma Analyzed by Machine Learning Classifiers
Invest. Ophthalmol. Vis. Sci., September 1, 2004; 45(9): 3144 - 3151.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
F. A. Medeiros, L. M. Zangwill, C. Bowd, and R. N. Weinreb
Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II Confocal Scanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomograph for the Detection of Glaucoma
Arch Ophthalmol, June 1, 2004; 122(6): 827 - 837.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology