IOVS Proceedings of the National Academy of Sciences
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:3476-3484.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.03-0122

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schaal, S.
Right arrow Articles by Dovrat, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schaal, S.
Right arrow Articles by Dovrat, A.

Lenticular Oxygen Toxicity

Shlomit Schaal,1 Itzchak Beiran,1,2 Irit Rubinstein,3 Benjamin Miller,1,2 and Ahuva Dovrat4

1From the Alberto Moscona Department of Ophthalmology, Rambam Medical Center, Haifa, Israel; and the 2Departments of Ophthalmology, 3Physiology and Biophysics, and 4Anatomy and Cell Biology, The Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.

PURPOSE. To investigate the possible toxic effect of oxygen on lenses in an organ culture.

METHODS. Bovine lenses were exposed to four different combinations of ambient pressure and oxygen concentration in an organ culture throughout a 7-day period. Lens transparency, histology, enzymatic activities, and photomicrographs were compared in study and control groups.

RESULTS. No differences were observed between study and control lenses in all measured parameters in a group subjected to a single exposure of 100% oxygen under increased (i.e., hyperbaric) ambient conditions and a group exposed repeatedly to high ambient pressure and normal oxygen partial pressure. Decreased lenticular transparency and enzymatic activities along with structural changes were observed in lenses exposed repeatedly to 100% oxygen concentration under both normal and increased ambient pressures. The observed changes were oxygen-load–dependent: the higher the oxygen partial pressure and the longer the time of exposure, the more severe the changes observed. Optical and structural changes in the lens occurred in a centripetal orientation: the greater the oxygen load, the more central the damage.

CONCLUSIONS. High oxygen load has a toxic effect on bovine lenses in organ culture. These effects appear to be cumulative: the higher the oxygen partial pressure and the greater the number of exposures, the more severe the changes observed in the lenses. Changes marking toxicity follow the route of oxygen diffusion into the lens, from the periphery to the center. Cautious interpretation of the results may indicate a role of oxygen (and/or its derivatives) in human cataract formation.





This article has been cited by other articles:


Home page
IOVSHome page
Y.-B. Shui and D. C. Beebe
Age-Dependent Control of Lens Growth by Hypoxia
Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 1023 - 1029.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology