IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:3520-3525.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.03-0178

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tran, C. H.
Right arrow Articles by Hodson, S. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tran, C. H.
Right arrow Articles by Hodson, S. A.

Examination of Murine Tear Film

Cuong H. Tran,1 Caroline Routledge,1 Julian Miller,2 Frances Miller,2 and Stuart A. Hodson1

1From the Department of Optometry and Vision Sciences, Cardiff University, Cardiff, Wales, United Kingdom; and 2Cardos Scientific, Winchester, United Kingdom.

PURPOSE. To define spatially any free aqueous layer in murine tear film.

METHOD. A pre-zeroed microelectrode was touched to the superficial corneal epithelium and then raised in steps of 1 µm through the murine tear film into the air and then retraced along the same path. Other murine tear films were partially probed with a spatial resolution of 0.1 µm. The reference microelectrode was placed in a fragment of 3% polyacrylamide gel equilibrated against 154 mM NaCl and located on the nasal quadrant of the scleral conjunctiva. Other murine corneas were quick frozen in melting isopentane and freeze substituted or pretreated with cetylpyridinium chloride and then examined by transmission electron microscopy.

RESULTS. The recorded electrical profiles of the tear film were reproducible in each preparation and showed a relatively uniform positive electrical potential throughout their whole thickness, except within 0.5 µm of the epithelial surface when the potential reversed to negative values. The thickness of mouse tear film averaged 7.4 ± 0.8 µm (mean ± SD, n = 40). The electron microscope images showed the murine tear film to have a relatively uniform positive electron density throughout the thickness.

CONCLUSIONS. Electrical profiles of the murine tear film presented no evidence of a separate free aqueous phase. The tear film is observed as an aqueous gel that includes anion-exchanging polyelectrolytes throughout most of its thickness, but within 0.5 µm of the epithelial surface, it changes to cation-exchanging polyelectrolytes. Electron microscope images provide some supporting evidence.





This article has been cited by other articles:


Home page
IOVSHome page
H. Saaren-Seppala, M. Jauhiainen, T. M. T. Tervo, B. Redl, P. K. J. Kinnunen, and J. M. Holopainen
Interaction of Purified Tear Lipocalin with Lipid Membranes
Invest. Ophthalmol. Vis. Sci., October 1, 2005; 46(10): 3649 - 3656.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology