(Investigative Ophthalmology and Visual Science. 2003;44:3533-3543.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.02-1041

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jensen, R. J.
Right arrow Articles by Wyatt, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jensen, R. J.
Right arrow Articles by Wyatt, J.

Thresholds for Activation of Rabbit Retinal Ganglion Cells with an Ultrafine, Extracellular Microelectrode

Ralph J. Jensen,1 Joseph F. Rizzo, III,1,2 Ofer R. Ziv,1,3 Andrew Grumet,3 and John Wyatt3

1From The Center for Innovative Visual Rehabilitation, VA Medical Center, Boston, Massachusetts; the 2Department of Ophthalmology, Harvard Medical School and the Massachusetts Eye and Ear Infirmary, Boston, Massachusetts; and the 3Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts.

PURPOSE. To determine electrical thresholds required for extracellular activation of retinal ganglion cells as part of a project to develop an epiretinal prosthesis.

METHODS. Retinal ganglion cells were recorded extracellularly in retinas isolated from adult New Zealand White rabbits. Electrical current pulses of 100-µs duration were delivered to the inner surface of the retina from a 5-µm long electrode. In about half of the cells, the point of lowest threshold was found by searching with anodal current pulses; in the other cells, cathodal current pulses were used.

RESULTS. Threshold measurements were obtained near the cell bodies of 20 ganglion cells and near the axons of 19 ganglion cells. Both cathodal and anodal stimuli evoked a neural response in the ganglion cells that consisted of a single action potential of near-constant latency that persisted when retinal synaptic transmission was blocked with cadmium chloride. For cell bodies, but not axons, thresholds for both cathodal and anodal stimulation were dependent on the search method used to find the point of lowest threshold. With search and stimulation of matching polarity, cathodal stimuli evoked a ganglion cell response at lower currents (approximately one seventh to one tenth axonal threshold) than did anodal stimuli for both cell bodies and axons. With cathodal search and stimulation, cell body median thresholds were somewhat lower (approximately one half) than the axonal median thresholds. With anodal search and stimulation, cell body median thresholds were approximately the same as axonal median thresholds.

CONCLUSIONS. The results suggest that cathodal stimulation should produce lower thresholds, more localized stimulation, and somewhat better selectivity for cell bodies over axons than would anodal stimulation.





This article has been cited by other articles:


Home page
IOVSHome page
C. de Balthasar, S. Patel, A. Roy, R. Freda, S. Greenwald, A. Horsager, M. Mahadevappa, D. Yanai, M. J. McMahon, M. S. Humayun, et al.
Factors Affecting Perceptual Thresholds in Epiretinal Prostheses
Invest. Ophthalmol. Vis. Sci., June 1, 2008; 49(6): 2303 - 2314.
[Abstract] [Full Text] [PDF]


Home page
J. Neurosci.Home page
C. Sekirnjak, P. Hottowy, A. Sher, W. Dabrowski, A. M. Litke, and E. J. Chichilnisky
High-Resolution Electrical Stimulation of Primate Retina for Epiretinal Implant Design
J. Neurosci., April 23, 2008; 28(17): 4446 - 4456.
[Abstract] [Full Text] [PDF]


Home page
Journal of Bioactive and Compatible PolymersHome page
C. Scholz
Perspectives on: Materials Aspects for Retinal Prostheses
Journal of Bioactive and Compatible Polymers, September 1, 2007; 22(5): 539 - 568.
[Abstract] [PDF]


Home page
J. Neurophysiol.Home page
C. Sekirnjak, P. Hottowy, A. Sher, W. Dabrowski, A. M. Litke, and E. J. Chichilnisky
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
J Neurophysiol, June 1, 2006; 95(6): 3311 - 3327.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
S. I. Fried, H. A. Hsueh, and F. S. Werblin
A Method for Generating Precise Temporal Patterns of Retinal Spiking Using Prosthetic Stimulation
J Neurophysiol, February 1, 2006; 95(2): 970 - 978.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
R. J. Jensen, O. R. Ziv, and J. F. Rizzo III
Thresholds for Activation of Rabbit Retinal Ganglion Cells with Relatively Large, Extracellular Microelectrodes
Invest. Ophthalmol. Vis. Sci., April 1, 2005; 46(4): 1486 - 1496.
[Abstract] [Full Text] [PDF]