IOVS Molecular and Cellular Biology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:3790-3794.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.02-0946

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kaufmann, C.
Right arrow Articles by Thiel, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kaufmann, C.
Right arrow Articles by Thiel, M. A.

Intraocular Pressure Measurements Using Dynamic Contour Tonometry after Laser In Situ Keratomileusis

Claude Kaufmann,1 Lucas M. Bachmann,2 and Michael A. Thiel1

1From the Department of Ophthalmology and the 2Horten Center for Patient-Oriented Research, University of Zurich, Zurich, Switzerland.

PURPOSE. Thinning of the corneal stroma by laser in situ keratomileusis (LASIK) results in inaccurate low intraocular pressure (IOP) readings by Goldmann applanation tonometry (GAT). Dynamic contour tonometry (DCT) is a novel measuring technique, designed to measure IOP largely independent of corneal thickness and curvature. The purpose of this study was to compare IOP measurements using GAT and DCT in eyes undergoing LASIK for correction of myopia.

METHODS. In a prospective, single-center study, central corneal thickness (CCT) and IOP were measured in patients undergoing first-time LASIK for myopia. IOP was measured before and after surgery using GAT and DCT. The untreated contralateral eyes served as paired controls.

RESULTS. There was good concordance between the two tonometers in 62 normal eyes before LASIK. Corneal ablation of 90.0 ± 49.18 µm (median ± SD) reduced IOP readings as measured by GAT by 3.0 ± 1.9 mm Hg (P < 0.001). In contrast, no significant change in IOP readings was recorded by DCT (-0.2 mm Hg ± 1.5 mm Hg, P = 0.30). There was no change in IOP in the untreated control eyes as measured by GAT and DCT.

CONCLUSIONS. Significant decreases in IOP were recorded by GAT after LASIK for myopia. Measurements by DCT, however, did not reveal any significant changes in IOP.





This article has been cited by other articles:


Home page
IOVSHome page
T. Romppainen, L. M. Bachmann, C. Kaufmann, C. Kniestedt, M. Mrochen, and M. A. Thiel
Effect of Riboflavin-UVA Induced Collagen Cross-linking on Intraocular Pressure Measurement
Invest. Ophthalmol. Vis. Sci., December 1, 2007; 48(12): 5494 - 5498.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
A R Ismail, M Lamont, S Perera, D Khan-Lim, R Mehta, J D A Macleod, and D F Anderson
Comparison of IOP measurement using GAT and DCT in patients with penetrating keratoplasties
Br. J. Ophthalmol., July 1, 2007; 91(7): 980 - 981.
[Full Text] [PDF]


Home page
Arch OphthalmolHome page
M. C. Grieshaber, A. Schoetzau, C. Zawinka, J. Flammer, and S. Orgul
Effect of Central Corneal Thickness on Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Primary Open-angle Glaucoma
Arch Ophthalmol, June 1, 2007; 125(6): 740 - 744.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. M. Martinez-de-la-Casa, J. Garcia-Feijoo, A. Fernandez-Vidal, C. Mendez-Hernandez, and J. Garcia-Sanchez
Ocular Response Analyzer versus Goldmann Applanation Tonometry for Intraocular Pressure Measurements.
Invest. Ophthalmol. Vis. Sci., October 1, 2006; 47(10): 4410 - 4414.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
C. Kaufmann, L. M. Bachmann, Y. C. Robert, and M. A. Thiel
Ocular Pulse Amplitude in Healthy Subjects as Measured by Dynamic Contour Tonometry.
Arch Ophthalmol, August 1, 2006; 124(8): 1104 - 1108.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
A Kotecha, E T White, J M Shewry, and D F Garway-Heath
The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry
Br. J. Ophthalmol., December 1, 2005; 89(12): 1572 - 1575.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
C. Kniestedt, S. Lin, J. Choe, A. Bostrom, M. Nee, and R. L. Stamper
Clinical Comparison of Contour and Applanation Tonometry and Their Relationship to Pachymetry
Arch Ophthalmol, November 1, 2005; 123(11): 1532 - 1537.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
P-A Tonnu, T Ho, T Newson, A El Sheikh, K Sharma, E White, C Bunce, and D Garway-Heath
The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry
Br. J. Ophthalmol., July 1, 2005; 89(7): 851 - 854.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
E Chihara, H Takahashi, K Okazaki, M Park, and M Tanito
The preoperative intraocular pressure level predicts the amount of underestimated intraocular pressure after LASIK for myopia
Br. J. Ophthalmol., February 1, 2005; 89(2): 160 - 164.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
C. Kaufmann, L. M. Bachmann, and M. A. Thiel
Comparison of Dynamic Contour Tonometry with Goldmann Applanation Tonometry
Invest. Ophthalmol. Vis. Sci., September 1, 2004; 45(9): 3118 - 3121.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology