IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:4140-4146.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.02-1067

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Felius, J.
Right arrow Articles by Swanson, W. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Felius, J.
Right arrow Articles by Swanson, W. H.

Effects of Cone Adaptation on Variability in S-Cone Increment Thresholds

Joost Felius1,2 and William H. Swanson1,3

1From the Retina Foundation of the Southwest, Dallas, Texas; the 2Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, Texas; and the 3Glaucoma Institute, State University of New York (SUNY) College of Optometry, New York, New York.

PURPOSE. Short-wavelength automated perimetry (SWAP) has gained popularity as a clinical tool for the assessment of short-wavelength–sensitive (S)-cone visual function, but has also been shown to have higher threshold variability than conventional achromatic perimetry, possibly due to an imbalance between S-cone adaptation and long (L)- and medium (M)-wavelength–sensitive cone adaptation. To investigate potential causes for this relatively high variability, we studied the effects of luminance and S-cone adaptation on variability in S-cone increment thresholds.

METHODS. Foveal S-cone increment thresholds were measured on adapting backgrounds ranging from 1.17 to 4.17 log troland (Td) and from -0.16 to 3.66 log S-cone trolands (TdS). Within-session variability (slope of the psychometric function) was evaluated in 2 trained and 15 inexperienced normal observers. Test–retest variability was evaluated in the 2 trained observers, and interobserver variability in the group of 15 observers. Multiple linear regression was used to model the effects of log luminance, log S-cone adaptation, and second-site polarization (ratio of luminance and S-cone adaptation; log [Td/TdS]).

RESULTS. Test–retest variability was lower for conditions with higher levels of S-cone adaptation (F = 9.04, P = 0.013, for the trained observers). Adaptation conditions with lower levels of polarization were associated with lower within-session variability (F = 6.9, P = 0.011; trained observers) and interobserver variability (F = 33.7, P = 0.004; group of 15 observers).

CONCLUSIONS. Variability of S-cone increment thresholds can be reduced by using adaptation conditions with a higher level of S-cone adaptation and/or a more balanced ratio between luminance and S-cone adaptation than is used for SWAP.





This article has been cited by other articles:


Home page
IOVSHome page
A. Eisner, M. D. Toomey, L. J. Incognito, J. P. O'Malley, and J. R. Samples
Contrasting Blue-on-Yellow with White-on-White Visual Fields: Roles of Visual Adaptation for Healthy Peri- or Postmenopausal Women Younger Than 70 Years of Age
Invest. Ophthalmol. Vis. Sci., December 1, 2006; 47(12): 5605 - 5614.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
E D Gilmore, C Hudson, R K Nrusimhadevara, and P T Harvey
Frequency of seeing characteristics of the short wavelength sensitive visual pathway in clinically normal subjects and diabetic patients with focal sensitivity loss
Br. J. Ophthalmol., November 1, 2005; 89(11): 1462 - 1467.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology