IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2004;45:351-360.)
© 2004 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.03-0265

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (24)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cheng, X.
Right arrow Articles by Bradley, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cheng, X.
Right arrow Articles by Bradley, A.

Test–Retest Reliability of Clinical Shack-Hartmann Measurements

Xu Cheng, Nikole L. Himebaugh, Pete S. Kollbaum, Larry N. Thibos, and Arthur Bradley

From the School of Optometry, Indiana University, Bloomington, Indiana.

PURPOSE. To evaluate the stability of clinical monochromatic aberrometry measurements over a wide range of time scales.

METHODS. Monochromatic aberrations in four normal eyes were measured with a clinical Shack-Hartmann aberrometer. A chin rest or a supplemental bite bar attachment was used to stabilize head and eye position. Five repeated measurements were taken within one test (5 frames, t < 1 second) without realignment. With realignment between each measurement, aberration measurements were repeated five times (t < 1 hour) on each day, at the same time of day on five consecutive days, and again on 5 days at monthly intervals. A control experiment studied the effect of systematically misaligning the eye to determine whether fixation errors can account for the variation in the repeated measurements.

RESULTS. Variability of wavefront root mean square (RMS) error (excluding defocus and astigmatism) was tracked across repeated measurements. Variances for different time scales were: 8.10 x 10-5 µm2 (t < 1 second), 3.24 x 10-4 µm2 (t < 1 hour), 4.41 x 10-4 µm2 (t < 1 week), 9.73 x 10-4 µm2 (t < 1 year). Bite bar and chin rest data were almost identical. Rotational fixation error up to 3° accounts for only part of the variability.

CONCLUSIONS. Increased variability in aberration maps between days and months indicates biological fluctuations that are large enough to prevent achievement of "perfect vision," even in the unlikely event that spherical and astigmatic refractive errors are corrected perfectly. However, lack of stability does not justify withholding treatment. A lasting benefit of aberration correction is expected despite temporal variability.





This article has been cited by other articles:


Home page
IOVSHome page
Y. Tian and C. F. Wildsoet
Diurnal fluctuations and developmental changes in ocular dimensions and optical aberrations in young chicks.
Invest. Ophthalmol. Vis. Sci., September 1, 2006; 47(9): 4168 - 4178.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the Association for Research in Vision and Ophthalmology