IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2004;45:63-70.)
© 2004 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.03-0294

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (13)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stone, R. A.
Right arrow Articles by Schmid, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stone, R. A.
Right arrow Articles by Schmid, G.

Diurnal Axial Length Fluctuations in Human Eyes

Richard A. Stone,1,2 Graham E. Quinn,1,2 Ellie L. Francis,1 Gui-shuang Ying,2 D. Ian Flitcroft,3 Parag Parekh,1 Jamin Brown,1 Joshua Orlow,1 and Gregor Schmid4

1From the Division of Pediatric Ophthalmology, The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania; the 2Department of Ophthalmology, Scheie Eye Institute-University of Pennsylvania, Philadelphia, Pennsylvania; the 3The Children’s Hospital, Dublin, Ireland; and the 4Pennsylvania College of Optometry, Philadelphia, Pennsylvania.

PURPOSE. This study sought diurnal variations of eye length in human subjects, analogous to those reported in laboratory animals.

METHODS. Seventeen subjects, ages 7 to 53 (median 16) years and mean spherical equivalent refractive error -0.68 D (range, -3.00 to +1.00 D), underwent axial length measurements at multiple times during the day between 7 AM and 1 AM the following day, using partial coherence interferometry (PCI), a highly precise, noncontact method. Diurnal axial length measurements were obtained on two or more days in 10 of these subjects.

RESULTS. During at least 1 day, 15 subjects showed a statistically significant (ANOVA, P < 0.05) diurnal fluctuation of axial length, with a magnitude generally between 15 and 40 µm. From the diurnal tracings that fit a sine curve using statistical criteria, the mean period of fluctuation was 21.6 ± 4.33 hours (SD), the mean amplitude was 27.1 ± 11.9 µm (SD; range, 12.8–41.4 µm), and the maximum axial length tended to occur at midday. Each of the subjects with multiple daily measurements showed axial length fluctuations on at least 1 day, but there were day-to-day differences in the diurnal variations: most notably, four subjects showed axial length fluctuations on each day; in others, the fluctuations were not observed on each testing day.

CONCLUSIONS. The human eye undergoes diurnal fluctuations in axial length, with a pattern suggesting maximum axial length at midday. Based on repeated measurements, these daily fluctuations may not appear regularly in all subjects, suggesting the possibility of physiologic influences that must be defined.





This article has been cited by other articles:


Home page
IOVSHome page
S. A. Read, M. J. Collins, and D. R. Iskander
Diurnal Variation of Axial Length, Intraocular Pressure, and Anterior Eye Biometrics
Invest. Ophthalmol. Vis. Sci., July 1, 2008; 49(7): 2911 - 2918.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
Y. Tian and C. F. Wildsoet
Diurnal fluctuations and developmental changes in ocular dimensions and optical aberrations in young chicks.
Invest. Ophthalmol. Vis. Sci., September 1, 2006; 47(9): 4168 - 4178.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
L. B. Wilson, G. E. Quinn, G.-s. Ying, E. L. Francis, G. Schmid, A. Lam, J. Orlow, and R. A. Stone
The Relation of Axial Length and Intraocular Pressure Fluctuations in Human Eyes
Invest. Ophthalmol. Vis. Sci., May 1, 2006; 47(5): 1778 - 1784.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
E. A. H. Mallen, P. Kashyap, and K. M. Hampson
Transient Axial Length Change during the Accommodation Response in Young Adults.
Invest. Ophthalmol. Vis. Sci., March 1, 2006; 47(3): 1251 - 1254.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. A. S. Rada and A. F. Wiechmann
Melatonin Receptors in Chick Ocular Tissues: Implications for a Role of Melatonin in Ocular Growth Regulation
Invest. Ophthalmol. Vis. Sci., January 1, 2006; 47(1): 25 - 33.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the Association for Research in Vision and Ophthalmology