IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2004;45:1464-1472.)
© 2004 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.03-1069

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (14)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Khoobehi, B.
Right arrow Articles by Kawano, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Khoobehi, B.
Right arrow Articles by Kawano, H.

Hyperspectral Imaging for Measurement of Oxygen Saturation in the Optic Nerve Head

Bahram Khoobehi,1 James M. Beach,1,2 and Hiroyuki Kawano1

1From the LSU Eye Center, Louisiana State University Health Sciences Center, New Orleans, Louisiana; and the 2Institute for Technology Development, Stennis Space Center, Mississippi.

PURPOSE. To evaluate a hyperspectral imaging technique for monitoring relative spatial changes in retinal oxygen saturation.

METHODS. The optic nerve head (ONH) and overlying vessels in cynomolgus monkey eyes were imaged with a fundus camera attached to a hyperspectral imaging system. Images were acquired with inspiration of room air and pure oxygen and at controlled intraocular pressures (IOP) of 15 mm Hg (normal) and 60 mm Hg (sustained for up to 5 minutes). Changes in relative blood oxygen saturation in the vessels and ONH were assessed from reflectance spectra. Saturation maps were derived from contributions of oxygenated and deoxygenated hemoglobin spectral signatures extracted from hyperspectral images. The results obtained with hyperspectral imaging were compared with known experimental outcomes.

RESULTS. Pure oxygen markedly increased oxygen saturation in veins. Increases in arteries and the ONH were smaller. The results obtained with hyperspectral image analysis agreed with known changes in oxygen saturation from breathing experiments. Raising IOP reduced saturation in all structures and resulted in profound desaturation of arteries. During sustained high IOP, a rebound in saturation was observed in the ONH. Spatial maps clearly showed the saturation changes in arteries, veins, and surrounding tissues.

CONCLUSIONS. Hyperspectral imaging can be adapted to measure and map relative oxygen saturation in retinal structures and the ONH in nonhuman primate eyes.





This article has been cited by other articles:


Home page
IOVSHome page
S. H. Hardarson, A. Harris, R. A. Karlsson, G. H. Halldorsson, L. Kagemann, E. Rechtman, G. M. Zoega, T. Eysteinsson, J. A. Benediktsson, A. Thorsteinsson, et al.
Automatic Retinal Oximetry
Invest. Ophthalmol. Vis. Sci., November 1, 2006; 47(11): 5011 - 5016.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
T. K. Stepinac, S. R. Chamot, E. Rungger-Brandle, P. Ferrez, J.-L. Munoz, H. van den Bergh, C. E. Riva, C. J. Pournaras, and G. A. Wagnieres
Light-Induced Retinal Vascular Damage by Pd-porphyrin Luminescent Oxygen Probes
Invest. Ophthalmol. Vis. Sci., March 1, 2005; 46(3): 956 - 966.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the Association for Research in Vision and Ophthalmology