IOVS Heart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2004;45:1963-1968.)
© 2004 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.03-0874

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsilimbaris, M. K.
Right arrow Articles by D’Amico, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsilimbaris, M. K.
Right arrow Articles by D’Amico, D. J.

Retinal Microvascular Surgery: A Feasibility Study

Miltiadis K. Tsilimbaris,1,2 Eugene S. Lit,1,2 and Donald J. D’Amico1,2

1From the Retina Service of the Massachusetts Eye and Ear Infirmary, and the 2Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts.

PURPOSE. To evaluate the feasibility of microvascular surgery at the level of the retinal vasculature.

METHOD. Porcine eyes were used, and eyecups were prepared under an operating microscope. Several classic microvascular maneuvers were explored, such as vascular puncturing, catheterization, mobilization, intravascular injections, and various combinations of the same. Instruments used ranged from disposable 30-gauge needles to an Er:YAG laser. Commercially available 10-0 nylon sutures, fine polyimide tubes, and custom-made fine glass tubes were used for vascular catheterization.

RESULTS. Puncturing, mobilization, catheterization, and intravascular injection of retinal arteries and veins were possible. The connection of two remote retinal vessels with a fine tube was also achieved with the combination of these maneuvers.

CONCLUSIONS. The feasibility of performing several microvascular maneuvers on retinal arteries and veins was demonstrated in porcine eyes. Further experimentation and development of these findings in a living animal model could lead to the development of such microvascular maneuvers in humans.