IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2004;45:3113-3117.)
© 2004 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.04-0015

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leonardi, M.
Right arrow Articles by Renaud, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leonardi, M.
Right arrow Articles by Renaud, P.

First Steps toward Noninvasive Intraocular Pressure Monitoring with a Sensing Contact Lens

Matteo Leonardi,1 Peter Leuenberger,2 Daniel Bertrand,3 Arnaud Bertsch,1 and Philippe Renaud1

1From the Swiss Federal Institute of Technology, Microsystem Laboratory, Lausanne, Switzerland; the 2Department of Ophthalmology, Hopital Universitaire de Genève, Genève, Switzerland; and the 3Department of Physiology, Centre Médical Universitaire, Genève, Switzerland.

PURPOSE. To present a novel and minimally invasive approach to intraocular pressure (IOP) monitoring based on a sensing contact lens.

METHODS. The key element of this measurement method is a soft contact lens with an embedded microfabricated strain gauge allowing the measurement of changes in corneal curvature correlated to variations in IOP. A prototype of this sensing contact lens was adapted and tested on enucleated porcine eyes. To verify the measurement principle of the device, the posterior chamber of the pig eyes was cannulated and connected to a syringe pump and a pressure sensor for precise control of IOP. The measurements of the contact lens were then compared to the ones from the pressure sensor, while pressure variations were induced through the cannula.

RESULTS. Enucleated porcine eyes were stimulated with increasing and decreasing ramps of IOP. Measurements from the sensing contact lens and from the pressure sensor showed very good correlation, proving the high potential of this new measurement principle. In this study, a typical signal from the sensing contact lens obtained during the experiments is presented and discussed.

CONCLUSIONS. The sensing contact lens shows the potential for continuously monitoring IOP in enucleated porcine eyes. The ultimate step will be the validation of the system and the reproducibility of results in humans. The device is placed in the same way as a corrective contact lens, no anesthesia is required, and vision remains almost unimpaired. This device would allow minimally invasive IOP monitoring over prolonged periods, regardless of the patient’s position and activity, thus opening up new diagnostic and therapeutic methods for the management of glaucoma.





This article has been cited by other articles:


Home page
IOVSHome page
P. B. J. Vermeltfoort, T. G. van Kooten, G. M. Bruinsma, A. M. M. Hooymans, H. C. van der Mei, and H. J. Busscher
Bacterial Transmission from Contact Lenses to Porcine Corneas: An Ex Vivo Study
Invest. Ophthalmol. Vis. Sci., June 1, 2005; 46(6): 2042 - 2046.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the Association for Research in Vision and Ophthalmology