IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2004;45:3118-3121.)
© 2004 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.04-0018

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (41)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kaufmann, C.
Right arrow Articles by Thiel, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kaufmann, C.
Right arrow Articles by Thiel, M. A.

Comparison of Dynamic Contour Tonometry with Goldmann Applanation Tonometry

Claude Kaufmann,1 Lucas M. Bachmann,2 and Michael A. Thiel1

1From the Department of Ophthalmology and the 2Horten Centre, University of Zurich, Zurich, Switzerland.

PURPOSE. The dynamic contour tonometer (DCT; Pascal tonometer) is a novel tonometer designed to measure intraocular pressure (IOP) independent of corneal properties. The purpose of this study was a comparison of the DCT with the Goldmann applanation tonometer (GAT) with respect to mean of IOP readings, the influence of ocular structural factors on IOP readings, and both intra- and interobserver variability, in a large group of healthy subjects.

METHODS. In a prospective study of 228 eyes, IOP measurements by GAT and DCT were compared, and the effects of central corneal thickness (CCT), corneal curvature, axial length, and anterior chamber depth were analyzed. To evaluate intra- and interobserver variability, IOP was measured in eight eyes by four observers.

RESULTS. There was a high concordance between the IOP readings obtained by DCT and GAT. However, IOP readings were consistently higher with DCT than with GAT (median difference: +1.7 mm Hg, interquartile range [25th–75th percentile] = 0.8–2.7 mm Hg). In contrast to GAT, multivariable regression analysis showed no significant effect of corneal thickness, corneal curvature, astigmatism, anterior chamber depth, and axial length on DCT readings. For repeated measurements the intraobserver variability was 0.65 mm Hg for the DCT and 1.1 mm Hg for the GAT (P = 0.008). Interobserver variability was 0.44 mm Hg for the DCT and 1.28 mm Hg for the GAT (P = 0.017).

CONCLUSIONS. IOP measurements by DCT are highly concordant with IOP readings obtained from GAT but do not vary in CCT and have a lower intra- and interobserver variability. DCT seems to be an appropriate method of tonometry for routine clinical use.





This article has been cited by other articles:


Home page
IOVSHome page
S. A. Read, M. J. Collins, and D. R. Iskander
Diurnal Variation of Axial Length, Intraocular Pressure, and Anterior Eye Biometrics
Invest. Ophthalmol. Vis. Sci., July 1, 2008; 49(7): 2911 - 2918.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. G. Boehm, A. Weber, L. E. Pillunat, R. Koch, and E. Spoerl
Dynamic Contour Tonometry in Comparison to Intracameral IOP Measurements
Invest. Ophthalmol. Vis. Sci., June 1, 2008; 49(6): 2472 - 2477.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
T. Romppainen, L. M. Bachmann, C. Kaufmann, C. Kniestedt, M. Mrochen, and M. A. Thiel
Effect of Riboflavin-UVA Induced Collagen Cross-linking on Intraocular Pressure Measurement
Invest. Ophthalmol. Vis. Sci., December 1, 2007; 48(12): 5494 - 5498.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
A R Ismail, M Lamont, S Perera, D Khan-Lim, R Mehta, J D A Macleod, and D F Anderson
Comparison of IOP measurement using GAT and DCT in patients with penetrating keratoplasties
Br. J. Ophthalmol., July 1, 2007; 91(7): 980 - 981.
[Full Text] [PDF]


Home page
Arch OphthalmolHome page
M. C. Grieshaber, A. Schoetzau, C. Zawinka, J. Flammer, and S. Orgul
Effect of Central Corneal Thickness on Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Primary Open-angle Glaucoma
Arch Ophthalmol, June 1, 2007; 125(6): 740 - 744.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
A Cervino
Rebound tonometry: new opportunities and limitations of non-invasive determination of intraocular pressure.
Br. J. Ophthalmol., December 1, 2006; 90(12): 1444 - 1446.
[Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
J M Gonzalez-Meijome, J Jorge, A Queiros, P Fernandes, R Montes-Mico, J B Almeida, and M A Parafita
Age differences in central and peripheral intraocular pressure using a rebound tonometer
Br. J. Ophthalmol., December 1, 2006; 90(12): 1495 - 1500.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
J. G. Ravin and E. J. Higginbotham
Are we there yet? Celebrating the centennial of the schiotz tonometer.
Arch Ophthalmol, September 1, 2006; 124(9): 1337 - 1338.
[Full Text] [PDF]


Home page
Arch OphthalmolHome page
C. Kaufmann, L. M. Bachmann, Y. C. Robert, and M. A. Thiel
Ocular Pulse Amplitude in Healthy Subjects as Measured by Dynamic Contour Tonometry.
Arch Ophthalmol, August 1, 2006; 124(8): 1104 - 1108.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
A Kotecha, E T White, J M Shewry, and D F Garway-Heath
The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry
Br. J. Ophthalmol., December 1, 2005; 89(12): 1572 - 1575.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
C. Kniestedt, S. Lin, J. Choe, A. Bostrom, M. Nee, and R. L. Stamper
Clinical Comparison of Contour and Applanation Tonometry and Their Relationship to Pachymetry
Arch Ophthalmol, November 1, 2005; 123(11): 1532 - 1537.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
P-A Tonnu, T Ho, T Newson, A El Sheikh, K Sharma, E White, C Bunce, and D Garway-Heath
The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry
Br. J. Ophthalmol., July 1, 2005; 89(7): 851 - 854.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the Association for Research in Vision and Ophthalmology