IOVS Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2005;46:3730-3736.)
© 2005 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.05-0175

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bengtsson, B.
Right arrow Articles by Heijl, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bengtsson, B.
Right arrow Articles by Heijl, A.

Effects of Input Data on the Performance of a Neural Network in Distinguishing Normal and Glaucomatous Visual Fields

Boel Bengtsson, Dimitrios Bizios, and Anders Heijl

From the Department of Ophthalmology, Malmö University Hospital, Lund University, Malmö, Sweden.

PURPOSE. To compare the performance of neural networks for perimetric glaucoma diagnosis when using different types of data inputs: numerical threshold sensitivities, Statpac Total Deviation and Pattern Deviation, and probability scores based on Total and Pattern Deviation probability maps (Carl Zeiss Meditec, Inc., Dublin, CA).

METHODS. The results of SITA Standard visual field tests in 213 healthy subjects, 127 patients with glaucoma, 68 patients with concomitant glaucoma and cataract, and 41 patients with cataract only were included. The five different types of input data were entered into five identically designed artificial neural networks. Network thresholds were adjusted for each network. Receiver operating characteristic (ROC) curves were constructed to display the combinations of sensitivity and specificity.

RESULTS. Input data in the form of Pattern Deviation probability scores gave the best results, with an area of 0.988 under the ROC curve, and were significantly better (P < 0.001) than threshold sensitivities and numerical Total Deviations and Total Deviation probability scores. The second best result was obtained with numerical Pattern Deviations with an area of 0.980.

CONCLUSIONS. The choice of type of data input had important effects on the performance of the neural networks in glaucoma diagnosis. Refined input data, based on Pattern Deviations, resulted in higher sensitivity and specificity than did raw threshold values. Neural networks may have high potential in the production of useful clinical tools for the classification of visual field tests.





This article has been cited by other articles:


Home page
IOVSHome page
C. Bowd, J. Hao, I. M. Tavares, F. A. Medeiros, L. M. Zangwill, T.-W. Lee, P. A. Sample, R. N. Weinreb, and M. H. Goldbaum
Bayesian Machine Learning Classifiers for Combining Structural and Functional Measurements to Classify Healthy and Glaucomatous Eyes
Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 945 - 953.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
C. Boden, K. Chan, P. A. Sample, J. Hao, T.-W. Lee, L. M. Zangwill, R. N. Weinreb, and M. H. Goldbaum
Assessing Visual Field Clustering Schemes Using Machine Learning Classifiers in Standard Perimetry
Invest. Ophthalmol. Vis. Sci., December 1, 2007; 48(12): 5582 - 5590.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the Association for Research in Vision and Ophthalmology