IOVS Biophysical Journal
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2005;46:4578-4580.)
© 2005 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.05-0586

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (18)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Martinez-de-la-Casa, J. M.
Right arrow Articles by Garcia-Sanchez, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Martinez-de-la-Casa, J. M.
Right arrow Articles by Garcia-Sanchez, J.

Reproducibility and Clinical Evaluation of Rebound Tonometry

Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Alfredo Castillo, and Julian Garcia-Sanchez

From the Hospital Clinico San Carlos, Madrid, Instituto de Investigaciones Oftalmologicas Ramon Castroviejo, Universidad Complutense, Madrid, Spain.

PURPOSE. To establish the reproducibility of a rebound tonometer in humans and the effect of corneal thickness on measurements, comparing it with Goldmann applanation tonometer.

METHODS. In a first study designed to examine the reliability of the RBT, three experienced ophthalmologists undertook three consecutive intraocular pressure (IOP) measurements in 12 eyes of 12 normal subjects. A cross-sectional study was then performed to compare measurements obtained using the two tonometers in 147 eyes of 85 patients with ocular hypertension or glaucoma.

RESULTS. Intraobserver coefficients of correlation obtained in the reproducibility study were 0.82, 0.73, and 0.87. Interobserver correlation was 0.82. There was a good correlation between IOP readings obtained by the RBT and the GAT (r = 0.865, P < 0.0001). RBT readings were consistently higher than GAT measurements (median difference, 1.8 ± 2.8 mm Hg). A Bland-Altman plot indicated the 95% limits of agreement between the two methods were –3.7 to 7.3 mm Hg (slope = –0.022, P = 0.618). Using RBT, the point that best discriminated between patients with an IOP ≤ 21 mm Hg and those with >21 mm Hg, as determined by the GAT was >23 mm Hg (sensitivity, 70.5%; specificity, 95.1%). In terms of pachymetry, the two tonometers behaved in a similar way, with correlation observed between IOP measurements and central corneal thickness.

CONCLUSIONS. Rebound tonometry is a reproducible method of determining IOP in humans. In general, it tends to overestimate IOP compared with Goldmann applanation tonometry. The tonometers used in both methods are similarly affected by pachymetry.





This article has been cited by other articles:


Home page
IOVSHome page
A. P. Wells, D. F. Garway-Heath, A. Poostchi, T. Wong, K. C. Y. Chan, and N. Sachdev
Corneal Hysteresis but Not Corneal Thickness Correlates with Optic Nerve Surface Compliance in Glaucoma Patients
Invest. Ophthalmol. Vis. Sci., August 1, 2008; 49(8): 3262 - 3268.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. Moreno-Montanes, M. J. Maldonado, N. Garcia, L. Mendiluce, P. J. Garcia-Gomez, and M. Segui-Gomez
Reproducibility and Clinical Relevance of the Ocular Response Analyzer in Nonoperated Eyes: Corneal Biomechanical and Tonometric Implications
Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 968 - 974.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
A Cervino
Rebound tonometry: new opportunities and limitations of non-invasive determination of intraocular pressure.
Br. J. Ophthalmol., December 1, 2006; 90(12): 1444 - 1446.
[Full Text] [PDF]


Home page
Arch OphthalmolHome page
J. G. Ravin and E. J. Higginbotham
Are we there yet? Celebrating the centennial of the schiotz tonometer.
Arch Ophthalmol, September 1, 2006; 124(9): 1337 - 1338.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the Association for Research in Vision and Ophthalmology