IOVS Physiological Reviews
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2005;46:857-862.)
© 2005 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.04-1086

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Malbouisson, J. M. C.
Right arrow Articles by Rios, G. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Malbouisson, J. M. C.
Right arrow Articles by Rios, G. D.

Upper and Lower Eyelid Saccades Describe a Harmonic Oscillator Function

Jorge M. C. Malbouisson,1 Antonio Augusto Velasco e Cruz,2 André Messias,2 Lívio V. O. Leite,2 and Gilmasa D. Rios2

1From the Institute of Physics, Federal University of Bahia, Bahia, Brazil; and the 2Department of Ophthalmology, Otorhinolaryngology, and Head and Neck Surgery, School of Medicine of Ribeirão Preto, University of São Paulo, São Paulo, Brazil.

PURPOSE. To determine whether experimentally measured upper and lower eyelid saccades can be fitted to a mathematical function.

METHODS. A charge-coupled device video camera connected to a personal computer was used to record upper and lower eyelid saccades accompanying 20° and 40° of vertical eye rotation in 19 normal adult subjects. Movement analysis was performed with software that calculated the center of a blue spot in each frame. The damped harmonic oscillator model was used to fit all saccadic functions obtained.

RESULTS. All downward and upward saccades of both upper and lower eyelids were fitted with the underdamped solution of the model with correlation coefficients ranging from 0.980 to 0.999 (mean = 0.995). It was possible to measure maximum velocity at any time, amplitude, and duration of the saccade movements. For the upper eyelid, downward saccades were faster than upward saccades, a difference that was not observed for the lower eyelid. For both the upper and lower eyelids, the velocity of upward and downward movements reached a peak at approximately 0.05/0.06 second and then decreased. For both the upper and lower eyelid saccades, there was good linear correlation between amplitude and velocity. Overshoots were detected in the downward saccades of both lids.

CONCLUSIONS. Normal upper and lower saccades are described by functions that are extremely well fitted by the underdamped solution of the harmonic oscillator model. Overshooting is a typical feature of normal downward saccades and can be explained by the elastic properties of the tissues.





This article has been cited by other articles:


Home page
IOVSHome page
M. F. Falcao, J. M. C. Malbouisson, A. A. V. Cruz, and A. Messias
The Relationship between Two Types of Upper Eyelid Movements: Saccades and Pursuit
Invest. Ophthalmol. Vis. Sci., June 1, 2008; 49(6): 2444 - 2448.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the Association for Research in Vision and Ophthalmology