1From the Department of Ophthalmology, Caritas Medical Centre, Hong Kong, Peoples Republic of China; and the 2Departments of Ophthalmology and Visual Sciences and 3Physiology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, Peoples Republic of China.
PURPOSE. To evaluate the performance of retinal nerve fiber layer (RNFL) thickness and optic nerve head (ONH) parameters analyzed with different offsets of reference plane in detecting early glaucomatous changes and in correlation with visual function using optical coherence tomography (OCT).
METHODS. This was a cross-sectional study consisting of 41 normal subjects and 30 with early and 40 with advanced glaucoma. RNFL thickness and ONH parameters were measured with reference planes positioned at 95, 150, and 205 µm above the level of retinal pigment epithelium (RPE). Discriminating power for early glaucoma detection and correlation with visual field MD for each parameter at different levels of reference plane were compared by using the analyses of area under the receiver operating characteristic curves (AUCs) and linear regression, respectively.
RESULTS. All ONH measurements were significantly different between normal and glaucoma groups, irrespective of the level of reference plane. In normal eyes, changing the reference plane position resulted in significant differences in ONH measurements. Among all the parameters examined, integrated rim volume and RNFL thickness measured at 150 µm above the RPE showed the largest AUC (0.966) for early glaucoma detection, and the strongest correlation with visual function (r = 0.793), respectively.
CONCLUSIONS. OCT analysis of the ONH and RNFL is useful for early glaucoma detection. Among the three reference planes examined in this study, measurements analyzed at 150 µm above the RPE demonstrated the best performance for glaucoma detection and correlation with visual function. Compared with ONH measurements, RNFL thickness may be a better indicator, reflecting retinal ganglion cell function and monitoring disease progression.
This article has been cited by other articles:
![]() |
C. K.-s. Leung, A. C. K. Cheng, K. K. L. Chong, K. S. Leung, S. Mohamed, C. S. L. Lau, C. Y. L. Cheung, G. C.-h. Chu, R. Y. K. Lai, C. C. P. Pang, et al. Optic Disc Measurements in Myopia with Optical Coherence Tomography and Confocal Scanning Laser Ophthalmoscopy Invest. Ophthalmol. Vis. Sci., July 1, 2007; 48(7): 3178 - 3183. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Ajtony, Z. Balla, S. Somoskeoy, and B. Kovacs Relationship between Visual Field Sensitivity and Retinal Nerve Fiber Layer Thickness as Measured by Optical Coherence Tomography Invest. Ophthalmol. Vis. Sci., January 1, 2007; 48(1): 258 - 263. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. A. Medeiros, L. M. Zangwill, C. Bowd, P. A. Sample, and R. N. Weinreb Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma. Invest. Ophthalmol. Vis. Sci., March 1, 2006; 47(3): 1008 - 1015. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. K.-s. Leung, K. K.-L. Chong, W.-m. Chan, C. K.-F. Yiu, M.-y. Tso, J. Woo, M.-K. Tsang, K.-k. Tse, and W.-h. Yung Comparative Study of Retinal Nerve Fiber Layer Measurement by StratusOCT and GDx VCC, II: Structure/Function Regression Analysis in Glaucoma Invest. Ophthalmol. Vis. Sci., October 1, 2005; 46(10): 3702 - 3711. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |