(Investigative Ophthalmology and Visual Science. 2005;46:1540-1548.)
© 2005 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.04-0968

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (15)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Anderson, A. J.
Right arrow Articles by Werner, J. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Anderson, A. J.
Right arrow Articles by Werner, J. S.

Characteristics of the Normative Database for the Humphrey Matrix Perimeter

Andrew John Anderson,1 Chris A. Johnson,1 Murray Fingeret,2 John L. Keltner,3 Paul G. D. Spry,4 Michael Wall,5 and John S. Werner3

1From Discoveries in Sight, Devers Eye Institute, Portland, Oregon; the 2Department of Optometry, The VA NY Health Care System, Brooklyn, New York; the 3Department of Ophthalmology, University of California Davis, Sacramento, California; the 4Bristol Eye Hospital, Bristol, United Kingdom; and the 5Department of Neurology, University of Iowa College of Medicine, Iowa City, Iowa.

PURPOSE. The Humphrey Matrix (Carl Zeiss Meditec, Dublin CA; Welch-Allyn, Skaneateles, NY) is a high-spatial-resolution perimeter that uses frequency-doubling stimuli. It incorporates an efficient test strategy that assumes that age, eccentricity, and test procedure type have only small effects on sensitivity. The results used to create the normative database for the perimeter were examined, to see whether these assumptions were met and to examine the form of the normative data.

METHOD. Visual fields were measured (Matrix 30-2, 24-2, 10-2 and Macula patterns) in >275 subjects judged to be normal by a battery of clinical procedures. The right eye was always tested first.

RESULTS. Sensitivity decreased by approximately 0.7 dB per age decade across all eccentricities; sensitivity decreased with eccentricity, typically by <5 dB at the most peripheral points tested. Although there was no systematic difference in sensitivity between the 30-2 and 24-2 tests, the Macula test sensitivities were typically 1 dB higher than for the 10-2 test. Sensitivity in the left eye was slightly lower than in the right, with the difference being significantly greater in the temporal visual field. In most test locations, the 95% confidence interval of normal sensitivity was approximately 6 dB below the median sensitivity.

CONCLUSIONS. The performance of the test strategy in the Matrix perimeter is appropriately matched to the response characteristics of the normal population. The finding of a spatially nonuniform difference in sensitivity between left and right eyes is attributable to light-adaptation differences between the eyes. This effect is accounted for in the perimeter’s normative database.





This article has been cited by other articles:


Home page
IOVSHome page
C. Q. Huang, J. Carolan, D. Redline, P. Taravati, K. R. Woodward, C. A. Johnson, M. Wall, and J. L. Keltner
Humphrey Matrix Perimetry in Optic Nerve and Chiasmal Disorders: Comparison with Humphrey SITA Standard 24-2
Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 917 - 923.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
L. Racette, F. A. Medeiros, L. M. Zangwill, D. Ng, R. N. Weinreb, and P. A. Sample
Diagnostic Accuracy of the Matrix 24-2 and Original N-30 Frequency-Doubling Technology Tests Compared with Standard Automated Perimetry
Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 954 - 960.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
H. K. Falkenberg and P. J. Bex
Sources of Motion-Sensitivity Loss in Glaucoma
Invest. Ophthalmol. Vis. Sci., June 1, 2007; 48(6): 2913 - 2921.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. Turpin, D. Jankovic, and A. M. McKendrick
Retesting Visual Fields: Utilizing Prior Information to Decrease Test-Retest Variability in Glaucoma
Invest. Ophthalmol. Vis. Sci., April 1, 2007; 48(4): 1627 - 1634.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
L. M. Sakata, J. DeLeon-Ortega, S. N. Arthur, B. E. Monheit, and C. A. Girkin
Detecting Visual Function Abnormalities Using the Swedish Interactive Threshold Algorithm and Matrix Perimetry in Eyes With Glaucomatous Appearance of the Optic Disc
Arch Ophthalmol, March 1, 2007; 125(3): 340 - 345.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. J. Anderson and A. M. McKendrick
Quantifying Adaptation and Fatigue Effects in Frequency Doubling Perimetry
Invest. Ophthalmol. Vis. Sci., February 1, 2007; 48(2): 943 - 948.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
F. A. Medeiros, P. A. Sample, L. M. Zangwill, J. M. Liebmann, C. A. Girkin, and R. N. Weinreb
A statistical approach to the evaluation of covariate effects on the receiver operating characteristic curves of diagnostic tests in glaucoma.
Invest. Ophthalmol. Vis. Sci., June 1, 2006; 47(6): 2520 - 2527.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the Association for Research in Vision and Ophthalmology