IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2006;47:4410-4414.)
© 2006 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.06-0158

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Martinez-de-la-Casa, J. M.
Right arrow Articles by Garcia-Sanchez, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Martinez-de-la-Casa, J. M.
Right arrow Articles by Garcia-Sanchez, J.

Ocular Response Analyzer versus Goldmann Applanation Tonometry for Intraocular Pressure Measurements

Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and Julian Garcia-Sanchez

From the Hospital Clínico San Carlos, and Instituto de Investigaciones Oftalmologicas Ramon Castroviejo, Universidad Complutense, Madrid, Spain

PURPOSE. To establish correlations between intraocular pressure (IOP) measurements obtained with the ocular response analyzer (ORA) and the Goldmann applanation tonometer (GAT). The effects of central corneal thickness on the measures obtained were also examined.

METHODS. This was a cross-sectional study. IOP was determined in 48 eyes of 48 patients with glaucoma In all patients, central corneal thickness (CCT) was measured by ultrasound pachymetry.

RESULTS. ORA readings were consistently higher than GAT measurements (Goldmann-correlated IOP – IOP GAT mean difference, 7.2 ± 3.5 mm Hg; corneal-compensated IOP – IOP GAT mean difference, 8.3 ± 4.0 mm Hg) However, differences were not constant and increased with increasing IOP GAT readings, both with respect to Goldmann-correlated IOP (slope = 0.623, P < 0.0001) and corneal-compensated IOP (slope = 0.538, P < 0.0001). Both pressure measurements provided by the ORA showed significant correlation with CCT (CCT versus Goldmann-correlated IOP: r = 0.460, P = 0.001; CCT versus corneal-compensated IOP: r = 0.442, P = 0.001). No significant effects of corneal curvature or refraction on any of the pressures were observed.

CONCLUSIONS. The ORA significantly overestimates IOP compared with the GAT. Differences between both sets of measures increase as the GAT-determined IOP increases. ORA readings seem to be affected by central corneal thickness.





This article has been cited by other articles:


Home page
IOVSHome page
J. Moreno-Montanes, M. J. Maldonado, N. Garcia, L. Mendiluce, P. J. Garcia-Gomez, and M. Segui-Gomez
Reproducibility and Clinical Relevance of the Ocular Response Analyzer in Nonoperated Eyes: Corneal Biomechanical and Tonometric Implications
Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 968 - 974.
[Abstract] [Full Text] [PDF]

eLetters:

Read all eLetters

Ocular Response Analyzer Compared to Goldmann Tonometry Study Utilizes Anomalous Data
David A. Luce
IOVS Online, 12 Jan 2007 [Full text]
Author Response: ORA Compared to Goldmann Tonometry Study Utilizes Anomalous Data
Jose M. Martinez-de-la-Casa
IOVS Online, 12 Jan 2007 [Full text]



HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the Association for Research in Vision and Ophthalmology