IOVS British Journal of Pharmacology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2006;47:4651-4658.)
© 2006 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.06-0444

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (11)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tabernero, J.
Right arrow Articles by Artal, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tabernero, J.
Right arrow Articles by Artal, P.

Predicting the Optical Performance of Eyes Implanted with IOLs to Correct Spherical Aberration

Juan Tabernero,1 Patricia Piers,2 Antonio Benito,1 Manuel Redondo,3 and Pablo Artal1

From 1Laboratorio de Óptica, Departamento de Física, Universidad de Murcia, Murcia, Spain; 2Advanced Medical Optics, Groningen, The Netherlands; and 3Clínica Ircovision, Cartagena, Murcia, Spain.

PURPOSE. To use powerful modeling techniques for predicting the optical performance of eyes implanted with different types of intraocular lenses (IOLs). This approach will allow performance of "virtual cataract surgery," with different IOL designs that can be used and physical parameters that may occur during actual surgery—in particular, in IOLs that correct spherical aberration.

METHODS. A computer model was developed to predict the optical performance of individual eyes after IOL implantation. The approach was validated in a group of patients with eyes implanted with different IOLs. In these patients, corneal wavefront aberrations were calculated from elevations provided by videokeratography. Ocular aberrations were measured with a high-dynamic range Hartmann-Shack wavefront sensor. Misalignments (IOL tilt and decentration) were estimated with a new instrument, based on recording Purkinje images. This model of particular corneal aberrations and IOL parameters (intrinsic optical design details plus geometric location data) was used to estimate the total ocular aberrations after surgery and to compared them with actual aberrations measured directly with the wavefront sensor.

RESULTS. The aberrations of implanted eyes predicted by the individualized optical models were well correlated with the actual aberration measured in each subject. This result indicates that the approach is adequate in evaluating the actual optical performance of different types of lenses. The model allows a large number of "virtual" surgeries to be performed, to test the performance of current or future IOL designs.

CONCLUSIONS. A "virtual surgery" approach was designed to predict the optical performance in pseudophakic eyes. In each subject, it was possible to obtain the eye’s optical performance with a particular IOL and biometric data after surgery. Specifically, this modeling can be used to evaluate the tolerances to misalignments and depth of focus of IOLs correcting spherical aberration in actual eyes. This approach is quite powerful and is especially applicable to the study of current and future aberration-correction IOL designs.





This article has been cited by other articles:


Home page
IOVSHome page
J. Tabernero, S. D. Klyce, E. J. Sarver, and P. Artal
Functional Optical Zone of the Cornea
Invest. Ophthalmol. Vis. Sci., March 1, 2007; 48(3): 1053 - 1060.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the Association for Research in Vision and Ophthalmology