IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2006;47:1109-1112.)
© 2006 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.05-1118

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yu, D.-Y.
Right arrow Articles by Cringle, S. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yu, D.-Y.
Right arrow Articles by Cringle, S. J.

Oxygen Distribution in the Mouse Retina

Dao-Yi Yu and Stephen J. Cringle

From the Centre for Ophthalmology and Visual Science, The University of Western Australia, Perth, Western Australia.

PURPOSE. To make the first measurements of intraretinal oxygen distribution in the mouse, an animal model of increasing importance in ophthalmic research.

METHODS. Oxygen-sensitive microelectrodes were used to measure oxygen tension as a function of depth through the retina and choroid in anesthetized mice (n = 8). All measurements were performed under light-adapted conditions, with the animals spontaneously inspiring room air. The oxygen distribution in the avascular portion of the outer retina was analyzed by an established three-layer mathematical model that determines outer retinal oxygen consumption.

RESULTS. The intraretinal oxygen distribution in the inner retina in individual profiles was often characterized by sharp peaks associated with elements of the retinal microvasculature, but, in the outer retina, the oxygen distribution was much more predictable and reflected the high oxygen uptake of the photoreceptors. Average choroidal oxygen tension was 42.0 ± 1.2 mm Hg (mean ± SE), and PO2 at the surface of the retina was 21.7 ± 0.8 mm Hg. The average minimum oxygen tension in the outer retina was 4.2 ± 0.5 mm Hg. Average outer retinal oxygen consumption in the mouse was 193.3 ± 10.6 nL O2/min per square centimeter, which is similar to that previously reported in the outer retina in vascularized areas of retina in the rat and monkey using similar techniques.

CONCLUSIONS. The intraretinal oxygen distribution in the mouse is qualitatively and quantitatively similar to that in other species with vascularized retinas. The rate of oxygen consumption in the outer retina is also similar. These baseline data can now be used in studies employing mouse models of retinal disease.





This article has been cited by other articles:


Home page
IOVSHome page
D.-Y. Yu, S. J. Cringle, P. K. Yu, and E.-N. Su
Intraretinal Oxygen Distribution and Consumption during Retinal Artery Occlusion and Graded Hyperoxic Ventilation in the Rat
Invest. Ophthalmol. Vis. Sci., May 1, 2007; 48(5): 2290 - 2296.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
S. Wang and R. A. Linsenmeier
Hyperoxia Improves Oxygen Consumption in the Detached Feline Retina
Invest. Ophthalmol. Vis. Sci., March 1, 2007; 48(3): 1335 - 1341.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
S. J. Cringle, P. K. Yu, E.-N. Su, and D.-Y. Yu
Oxygen distribution and consumption in the developing rat retina.
Invest. Ophthalmol. Vis. Sci., September 1, 2006; 47(9): 4072 - 4076.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the Association for Research in Vision and Ophthalmology