IOVS Journal of Nutrition
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2006;47:1587-1593.)
© 2006 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.05-1187

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yu, P. K.
Right arrow Articles by Yu, D.-Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yu, P. K.
Right arrow Articles by Yu, D.-Y.

Experimental Retinal Ablation Using a Fourth-Harmonic 266 nm Laser Coupled with an Optical Fiber Probe

Paula K. Yu, Joseph Miller, Stephen J. Cringle, and Dao-Yi Yu

From the Centre for Ophthalmology and Visual Science, The University of Western Australia, Perth, Australia.

PURPOSE. To explore the ablation potential of 266 nm laser pulses, with an intact porcine retina preparation.

METHODS. Segments of porcine eyes were used in an in vitro preparation in which localized areas of intact retina and choroid could be exposed to 266 nm laser irradiation. The segments of ocular tissue were bathed in fluid, to mimic the intraocular environment. Contact between the probe and the retinal surface was established before the first laser pulse. Single or multiple pulses (5–7 ns duration) at fluence levels of 0.4 to 1.2 J/cm2 were delivered via a tapered fiber optic probe with a tip size of approximately 110 µm. The retinal tissue was then fixed and sectioned for histologic examination. The ablation depth and extent of damage were measured and related to fluence level and the number of pulses applied.

RESULTS. Ablation of the inner retina was achieved by single pulses at fluence levels of 0.6 J/cm2 and higher. The depth of retinal ablation was highly dependent on fluence for lesions generated with a single pulse but less so for multiple pulses (3–10), particularly at lower fluence levels. Higher numbers of pulses (50–100) did not increase ablation depth in a predictable manner.

CONCLUSIONS. Pulsed laser (266 nm) irradiation at low pulse counts and high fluence levels is a possible alternative for localized retinal ablation with minimal collateral damage in a fluid environment.