IOVS Drug Metabolism and Disposition
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2007;48:1038-1042.)
© 2007 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.06-0488

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Noguera, G.
Right arrow Articles by Behrens, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Noguera, G.
Right arrow Articles by Behrens, A.

Novel Laser-Activated Solder for Sealing Corneal Wounds

Guillermo Noguera,1 Woo-Seok Lee,1 Juan Castro-Combs,1 Roy S. Chuck,1 Barbara Soltz,2 Robert Soltz,2 and Ashley Behrens1

1From The Wilmer Ophthalmological Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland; and 2Conversion Energy Enterprises, Spring Valley, New York.

PURPOSE. To compare the effectiveness of a laser-activated biological tissue solder with that of standard sutures for sealing corneal incisions.

METHODS. Two keratome knives measuring either 3.0 mm or 2.85 mm were used to create a non–self-sealing peripheral oblique corneal wound (POCW) or a central perpendicular corneal wound (CPCW) in fresh rabbit cadaver eyes. Wounds were sealed with a solder strip (POCW; n = 5), a solder patch (CPCW; n = 5), or three interrupted nylon 10–0 sutures (n = 5). After the solder was placed on the wound, a diode laser was used to activate the solder, resulting in cross-linking to tissue. Wound stability was tested by a stepwise infusion of saline, and pressure changes were monitored with a digital manometer. Leaking pressure was recorded.

RESULTS. The pressurized mean baseline IOP in the intact globe was 131.13 mm Hg (SD, 4.66). Mean IOP after CPCW was 1.7 mm Hg (SD, 0.13); for POCW it was 3.62 mm Hg (SD, 3.09). For the CPCW group, the mean leaking pressure in the sutured eyes was 82.76 mm Hg (SD, 6.55), whereas in the solder patch it was 101.42 mm Hg (SD, 29.92; P = 0.2222). For the POCW group, the mean leaking pressure in the sutured eyes was 33.44 mm Hg (SD, 9.38), and the mean IOP achieved in the solder repaired eyes was 125.16 mm Hg (SD, 9.85; P = 0.0079).

CONCLUSIONS. The tested laser-activated solder was as effective as sutures when used as a patch and superior to sutures for clear corneal incisions in this animal ex vivo model.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS