IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2007;48:1261-1267.)
© 2007 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.06-0352

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wong, K.-H.
Right arrow Articles by Kooijman, A. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wong, K.-H.
Right arrow Articles by Kooijman, A. C.

Changes in Spherical Aberration after Lens Refilling with a Silicone Oil

Kwok-Hoi Wong,1 Steven A. Koopmans,1 Thom Terwee,2 and Aart C. Kooijman1

1From the Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands; and 2Advanced Medical Optics, Groningen, The Netherlands.

PURPOSE. It may be possible to restore accommodation to presbyopic human eyes by refilling the lens capsular bag with a soft polymer. In the present study, optical changes were measured that occurred in a pig eye model after the refilling of the capsular bag.

METHODS. The optical power and spherical aberration in 10 isolated pig lenses were measured under different conditions. They were first determined by using a scanning laser ray-tracing technique over an effective pupil size of 6 mm. Second, the contours of the anterior and posterior lens surface were photographed, and a mathematical ray-tracing was performed by using a polynomial fit through the digitized surface contours, to determine optical power and spherical aberration. Third, the lenses were refilled with a silicone oil until their preoperative lens thickness was reached, and scanning laser ray-tracing, contour photography, and mathematical ray-tracing were repeated. Comparisons between the measurements were made to determine how the change from a gradient refractive index to a homogeneous refractive index influenced spherical aberration. The influence of the change in lens contour on spherical aberration after lens refilling was also studied.

RESULTS. The natural lenses had a higher lens power than the refilled lenses (49.9 ± 1.5 D vs. 36.8 ± 1.5 D; P < 0.001). Moreover, there was a change in sign from negative spherical aberration before lens refilling (–3.6 D) to positive spherical aberration after lens refilling (7.9 D; P < 0.001). The comparison between scanning laser ray-tracing of the natural lens and mathematical ray-tracing of the photographed surface contours of the natural lens to determine the effect of refractive index substitution (i.e., replacement of a gradient refractive index by a homogeneous refractive index) showed a significant change in spherical aberration from –3.6 ± 2.0 to 11.0 ± 2.1 D (P < 0.001). The change in lens contour did not result in a significant change in spherical aberration (P = 0.08) before and after lens refilling with an equal refractive index.

CONCLUSIONS. The lower lens power of refilled pig lenses compared to natural lenses was due to the lower refractive index of the refill material. Refilling pig lenses with the silicone oil used in this study resulted in an increase in spherical aberration. This increase was mainly caused by the change from a gradient refractive index to a homogeneous refractive index. The change in lens curvature after lens refilling did not result in an increase in spherical aberration. The influence of lens refilling on spherical aberration of human lenses must be determined in similar experiments in human eyes.