IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2007;48:3026-3031.)
© 2007 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.04-0694

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shah, S.
Right arrow Articles by Cunliffe, I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shah, S.
Right arrow Articles by Cunliffe, I.

Assessment of the Biomechanical Properties of the Cornea with the Ocular Response Analyzer in Normal and Keratoconic Eyes

Sunil Shah,1,2,3 Mohammed Laiquzzaman,1 Rajan Bhojwani,3 Sanjay Mantry,1,3 and Ian Cunliffe1,2,3

1From the Birmingham Heartlands and Solihull NHS Trust, Solihull, United Kingdom; the 2Anterior Eye Group (AEG), Neurosciences Research Institute, Aston University, Birmingham, United Kingdom; and the 3Birmingham and Midland Eye Centre, Birmingham, United Kingdom.

PURPOSE. To compare hysteresis, a novel measure of ocular rigidity (viscoelasticity) in normal and keratoconic eyes.

METHODS. The study consisted of 207 normal and 93 keratoconic eyes. Eyes were diagnosed as keratoconic based on clinical examination and corneal topography. The hysteresis was measured by the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY). The data were recorded by Generation 3 software for the ORA. Central corneal thickness (CCT) was measured with a handheld ultrasonic pachymeter in the midpupillary axis.

RESULTS. The mean hysteresis was 10.7 ± 2.0 (SD) mm Hg (range, 6.1–17.6) in normal eyes compared with 9.6 ± 2.2 mm Hg (range, 4.7–16.7) in keratoconic eyes. The difference was statistically significant (P < 0.0001, unpaired t-test). Mean CCT in the normal and keratoconic eyes was 545.0 ± 36.4 µm (range, 471–650) and 491.8 ± 54.7 µm (range, 341–611), respectively; the difference was significant (P < 0.0001, unpaired t-test).

CONCLUSIONS. Hysteresis was significantly higher in normal than in keratoconic eyes. It may be a useful measurement in addition to CCT, when assessing ocular rigidity, and may be of particular importance when trying to correct intraocular measurements for increased or decreased ocular rigidity. Long-term studies of change in hysteresis may provide information on the progression of keratoconus.





This article has been cited by other articles:


Home page
IOVSHome page
L. Lim, G. Gazzard, Y.-H. Chan, A. Fong, A. Kotecha, E.-L. Sim, D. Tan, L. Tong, and S.-M. Saw
Cornea Biomechanical Characteristics and Their Correlates with Refractive Error in Singaporean Children
Invest. Ophthalmol. Vis. Sci., September 1, 2008; 49(9): 3852 - 3857.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
D. H. Glass, C. J. Roberts, A. S. Litsky, and P. A. Weber
A Viscoelastic Biomechanical Model of the Cornea Describing the Effect of Viscosity and Elasticity on Hysteresis
Invest. Ophthalmol. Vis. Sci., September 1, 2008; 49(9): 3919 - 3926.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the Association for Research in Vision and Ophthalmology